background image

14

80

100

8

4

120

80

100

12

P

U

S

H

RE

ET

S

Disconnect

Always

Air Supply

Disconnect

Always

Air Supply

DRAINING THE TANK

See Figure 9.

To help prevent tank corrosion and keep moisture out of the air 
used, the tank of the compressor should be drained daily. 
To drain:

  Turn the air compressor off.

  Pull the ring on the pressure relief valve to release until 

pressure gauge reads less than 0 psi. 

  Release the ring. 

  Rotate drain valve counterclockwise to open.

  Tilt tank as shown in figure 8 to drain moisture from tank 

into a suitable container. 

 

NOTE:  Condensate is a polluting material and should be 
disposed of in compliance with local regulations.

  If  drain  valve  is  clogged,  release  all  air  pressure,  

remove and clean valve, then reinstall.

WARNING:

Unplug the air compressor and release all air from the 
tank before servicing. Failure to depressurize tank before 
attempting to remove valve may cause serious personal 
injury.

  Rotate drain valve clockwise until tightly closed.

to 

oPen

tilt 

tanK

drain ValVe

WARNING: 

Always  disconnect  the  air  supply  and  power  supply   
before making adjustments, servicing a tool, or when a 
tool is not in use

.

OPERATION

TOOL BAG

See Figures 7 - 8.

The tool bag can be attached to the air compressor to store 
tools when they are not being used.
To attach:

  Locate the snap buttons on the tool bag and align them 

with the snaps on the air compressor frame. 

  Push down to snap into place. 

The tool bag can be used while it is on the air compressor 
to hold a variety of items, or it can be detached and used on 
a tool belt. To use this feature, simply detach the tool bag 
from the air compressor, slide a tool belt through the tool 
belt sleeve in the tool bag, and attach belt to waist. 

P

U

S

H

RE

ET

S

100

120

140

80

60

40

6

4 PRESSURE 

GAUGE

2

0

8

10

12

14

100

120

140

80

60

40

6

4 PRESS

URE GAUG

E

2

0

8

10

12

14

Disconnect

Always

Air Supply

Disconnect

Always

Air Supply

SnaP Button

tool BaG

CoMPreSSor FraMe

Fig. 7

Fig. 9

tool BaG

Fig. 8

tool Belt SleeVe

tool 

StoraGe

SnaPS

WARNING: 

Drain tank every day to prevent corrosion and possible 
injury due to tank damage.

Содержание H150PL

Страница 1: ...RNING To reduce the risk of injury the user must read and understand the operator s manual before using this product Thank you for buying a Husky product OPERATOR S MANUAL 1 5 Gallon PORTABLE Air Comp...

Страница 2: ...not equipped and should not be used to supply breathing quality air Additional equip ment would be necessary to properly filter and purify the air to meet minimal specifications for Grade D breathing...

Страница 3: ...l be required in some environments For example the working area may in clude exposure to a noise level which can lead to hearing damage The employer and user must ensure that any necessary hearing pro...

Страница 4: ...at pressure greater than 125 psi Risk of Injury Do not direct air stream at body Do not used compressed air for breathing Do not carry while painting If connected to a circuit protected by fuses use...

Страница 5: ...nd perform its intended function Check for alignment of moving parts bind ing of moving parts breakage of parts mounting and any other conditions that may affect its operation A guard or other part th...

Страница 6: ...s that involve your safety Do not spray flammable liquid in a confined area Spray area must be well ventilated Do not smoke while spraying or spray where spark or flame is present Keep compressors as...

Страница 7: ...efore beginning power tool operation always wear safety goggles or safety glasses with side shields and when needed a full face shield We recommend Wide Vision Safety Mask for use over eyeglasses or s...

Страница 8: ...ug Do not use an adapter with this product Electrical Fig 1 Extension Cords Useonly3 wireextensioncordsthathave3 pronggrounding plugs and 3 pole receptacles that accept the product s plug When using a...

Страница 9: ...Overload Switch Automatically shuts off the compressor if the temperature of the electric motor exceeds a predetermined limit glossary of terms Air Filter Porous element contained within a metal or pl...

Страница 10: ...Oil Free Gauges 2 in diameter Input 120 V 60 Hz AC only 8 5 Amps Net Weight 33 0 lbs 80 1 0 0 8 4 120 80 1 0 0 12 P U S H R E ET S D i s c o n n e c t A l w a y s A i r S u p p l y D i s c o n n e c...

Страница 11: ...an be detached from the air compressor and used on a tool belt FEATURES ASSEMBLY UNPACKING This product requires assembly n Carefully remove the product and any accessories from the box Make sure that...

Страница 12: ...you care less Remember that a careless fraction of a second is sufficient to inflict serious injury WARNING Always wear safety goggles or safety glasses with side shields when operating power tools Fa...

Страница 13: ...poses listed below Operating some light duty air powered tools Inflating tires air beds sports equipment etc Inflation accessories sold separately tURNING THE AIR COMPRESSOR On OFF See Figure 5 n Turn...

Страница 14: ...e clockwise until tightly closed TO OPEN TILT TANK DRAIN VALVE WARNING Always disconnect the air supply and power supply before making adjustments servicing a tool or when a tool is not in use operati...

Страница 15: ...Any continued loss of air after releasing the ring indicates a problem with the pressure relief valve Discontinue use and seek service before continued use of the air compressor warning If air leaks...

Страница 16: ...n blowing dust If operation is dusty also wear a dust mask WARNING Always release all pressure disconnect from power sup ply and allow unit to cool to the touch before cleaning or making repairs on th...

Страница 17: ...onnect other electrical appli ances from circuit or operate compres sor on its own branch circuit Check for proper gauge wire and cord length Take compressor to service center Push Button Overload pro...

Страница 18: ...n this operator s manual This warranty does not apply to any damage to the One World Technologies Inc product that is the result of improper maintenance or to any One World Technologies Inc product th...

Страница 19: ...NOTES...

Страница 20: ...pair parts always give the following information MODEL NUMBER SERIAL NUMBER H150PL OPERATOR S MANUAL 1 5 Gallon PORTABLE Air Compressor H150PL WARNING Some dust created by power sanding sawing grindin...

Отзывы: