Fig. 11
CHECKING THE PRESSURE RELIEF VALVE
See Figure 10 - 11.
DANGER:
Do not attempt to tamper with the pressure relief valve.
Anything loosened from this device could fly up and hit
you. Failure to heed this warning could result in death or
serious personal injury.
The pressure relief valve will automatically release air if the
air receiver pressure exceeds the preset maximum. The
valve should be checked before each day of use by pulling
the ring by hand.
Turn the air compressor on and allow the tank to fill. The
compressor will shut off when the pressure reaches the
preset maximum.
Turn the air compressor off.
Pull the ring on the pressure relief valve to release air for
three to five seconds.
Release the ring. Air must immediately stop escaping
when the ring is released. Any continued loss of air after
releasing the ring indicates a problem with the pressure
relief valve. Discontinue use and seek service before
continued use of the air compressor.
WARNING:
If air leaks after the ring has been released, or if the valve
is stuck and cannot be actuated by the ring, do not use
the air compressor until the pressure relief valve has been
replaced. Use of the air compressor in this condition
could result in serious personal injury.
PreSSure relieF ValVe
rinG
to releaSe air
CHeCK ValVe
PreSSure
relieF ValVe
RESET BUTTON
See Figure 12.
When amperage into the air compressor exceeds the specified
amperage, the air compressor will automatically shut off.
To reset the air compressor:
Turn the air compressor off.
Unplug the air compressor for 30 minutes.
NOTE: If the overload protector is actuated, the motor
must be allowed to cool down for 30 minutes before
manual resetting.
Press the reset button.
Plug the air compressor into an approved outlet.
Turn the air compressor on.