26
5.
SPECIFICATIONS
Table 10. Specifications by Model
ITEM UNIT
HH100
HH150-2
HH300-2 HH500-2 HH750-2 HH1000-2
Impact
Energy Class
ft-lbs.
kg-m
100
14
200
28
350
49
575
81
825
116
1200
168
Adjustable
Blows Per
Minute
bpm 700-1300 520-1170 590-1200 510-1,180
600-1080 500-860
Required Oil
Flow
gpm
l/min
4-7
20-45
5-12
20-45
8-16
30-60
9-18
35-70
13-24
50-90
16-35
60-130
Operating
Pressure
psi
bar
1,000-
2,275
69-160
1,014-
1,867
70-129
1,294-
1,867
89-129
1,441-
1,867
99-129
1,441-
2,161
99-149
1,720-2,587
119-178
Nitrogen Gas
Pressure
psi
bar
140-160
10-11
190-210
13-14
190-210
13-14
160-185
11-13
190-210
13-14
190-210
13-14
Total Weight
with Tool
lbs.
kg
165
154
340
154
520
236
550
250
800
363
1,100
500
Total Length
inch
mm
35
889
50
1,270
52
1,321
54
1,372
64
1,626
73
1,854
Tool Diameter
inch
mm
1.6
40
2.0
50
2.4
60
2.6
65
3.0
75
3.5
90
Applicable
Carrier
Tons
.75-2.25
1.25 – 3.25
2.25 - 6
2.75 - 7
3.35 – 8
3.5 - 12
Remarks:
•
The hammer is to be used within the specified oil pressure, oil flow and gas pressure parameters.
•
The carrier hydraulic system relief pressure is to be set at 600 to 800 psi above the hammer
“Operating Pressure” measured at the hose end of the carrier (pressure hose) when disconnected
from the hammer.
•
The nitrogen charge in a hammer is directly related to the operating pressure of the circuit
powering it. An increase of 10% in gas charge will cause a 10% rise in hammer operating
pressure. This is prevalent in hammers if gas pressure has been set or checked on a cool morning
(60
0
F) and then run in increasingly higher ambient temperatures up to and over 100
0
F. This
increase in ambient temperature can cause the carrier operating pressure to rise past its relief
setting, stalling the hammer.
Table 11. Recommended Gas Pressure Based Upon Ambient Temperature
*
*
Gas pressure should be set bearing in mind the possible high ambient temperature
potential for
that
day’s work. While unlikely,
a setting that will run well on a hot day
may run erratically until the hammer warms up thoroughly
. Please contact IPC
Industries, Inc. if you have any questions.
Hammer Model Standard Pressure
80
0
F 90
0
F 100
0
F 110
0
F 120
0
F
HH100
140 – 160 psi
160 psi
150 psi
140 psi
130 psi
120 psi
HH150-2
190 – 210 psi
210 psi
200 psi
190 psi
180 psi
170 psi
HH300-2
190 – 210 psi
210 psi
200 psi
190 psi
180 psi
170 psi
HH500-2
160 – 185 psi
185 psi
175 psi
160 psi
150 psi
140 psi
HH750-2
190 – 210 psi
210 psi
200 psi
190 psi
180 psi
170 psi
HH1000-2
190 – 210 psi
210 psi
200 psi
190 psi
180 psi
170 psi
Содержание HH100
Страница 1: ...HUSKIE HYDRAULIC HAMMERS SERVICE MANUAL HH100 HH150 2 HH300 2 HH500 2 HH750 2 HH1000 2 ...
Страница 2: ...2 ...
Страница 33: ...33 9 PARTS LIST AND ILLUSTRATIONS HH100 HH150 2 HH300 2 HH500 2 HH750 2 HH1000 2 ...
Страница 35: ...35 HH100 HAMMER Effective 07 09 ...
Страница 37: ...37 ...
Страница 39: ...39 HH150 2 HAMMER S N 001 099 2B2 1000 UP Effective 07 09 ...
Страница 41: ...41 ...
Страница 43: ...43 HH300 2 HAMMER S N 001 099 2E2 1000 UP Effective 07 09 ...
Страница 47: ......
Страница 49: ...49 HH500 2 HAMMER S N 001 099 2R2 1000 UP Effective 07 09 ...
Страница 55: ...55 HH750 2 HAMMER S N 001 099 2F2 1000 UP Effective 07 09 ...
Страница 59: ...59 ...
Страница 61: ...61 Effective 07 09 HH1000 2 HAMMER S N 001 099 2H2 1000 UP ...