10
UNDERWATER OPERATION
Operation of hydraulic hammers under water requires proper preparation to prevent
internal damage to hammer parts and carrier hydraulic system.
1. To prepare the hammer for underwater operation you will need
an external compressed air supply.
a. For HH100 through HH500-2, 5 –10 CFM at 50 to 90 psi is
adequate.
b. For HH750-2 and HH1000-2, 20 to 50 CFM is required.
2. Connect air supply line to front cap threaded port (remove plug
P/N 3Z01-FP0038 as shown.) Thread is 3/8 inch pipe tapered.
3. Set pressure regulator to 50 – 90 psi.
4. Maintain air supply to hammer at all times when operating
under water
PRESSURE REGULATOR
Figure 3. Air Compressor Supply