15
Table 4. Tightening Torque Requirements (Ft. lbs.)
HH100 HH150-2 HH300-2 HH500-2 HH750-2 HH1000-2
Side Rod
NA
400 ±35
550 ±35
NA
NA
NA
Side Rod Back Nut
NA
NA
NA
730 ±35
730 ±35
770 ±35
Front Cap Set Bolt
175 ±35
NA
NA
NA
NA
NA
Back Cap Set Bolt
175 ±35
NA
NA
NA
NA
NA
Bracket Bolt
150 ±35
260 ±35
260 ±35
260 ±35
260 ±35
400 ±35
GREASING REQUIREMENTS
The hammer should be greased each startup and after every 2-3 hours of operation. The
grease nipple is located at the front cap as shown in Figure 6. Approximately 10 shots in
the front cap are recommended when the tool is at the upper limit of travel.
Figure 6. Grease Fitting
Figure 6.
1
3
4
2
5
1
3
6
2
4
7
1
3
5
2
6
4
8
4
1
3
2
5
Figure 5. Tightening Sequence
Содержание HH100
Страница 1: ...HUSKIE HYDRAULIC HAMMERS SERVICE MANUAL HH100 HH150 2 HH300 2 HH500 2 HH750 2 HH1000 2 ...
Страница 2: ...2 ...
Страница 33: ...33 9 PARTS LIST AND ILLUSTRATIONS HH100 HH150 2 HH300 2 HH500 2 HH750 2 HH1000 2 ...
Страница 35: ...35 HH100 HAMMER Effective 07 09 ...
Страница 37: ...37 ...
Страница 39: ...39 HH150 2 HAMMER S N 001 099 2B2 1000 UP Effective 07 09 ...
Страница 41: ...41 ...
Страница 43: ...43 HH300 2 HAMMER S N 001 099 2E2 1000 UP Effective 07 09 ...
Страница 47: ......
Страница 49: ...49 HH500 2 HAMMER S N 001 099 2R2 1000 UP Effective 07 09 ...
Страница 55: ...55 HH750 2 HAMMER S N 001 099 2F2 1000 UP Effective 07 09 ...
Страница 59: ...59 ...
Страница 61: ...61 Effective 07 09 HH1000 2 HAMMER S N 001 099 2H2 1000 UP ...