![HURST ML-630-SI Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/hurst/ml-630-si/ml-630-si_instruction-manual_2187527029.webp)
29
NOTE:
Non-observance of the maintenance plan can lead to malfunctions that are not
covered by the warranty.
For dismantling the sparking plug, use a commercially-available sparking plug
spanner with universal joint and spanner size of 16 mm (5/8 inch).
A straight/rigid sparking plug spanner would damage or break off the sparking
plug!
(also observe the separate instructions from the engine manufacturer)
First month or after the fi rst 20 hours (fi rst time):
• Replace engine oil (see operating instructions of the engine manufacturer).
You must conduct the following service measures every 50 operating hours:
• Clean the air
¿
lter element.
• After using in a dusty environment, inspect the air
¿
lter element and clean immediately,
if necessary.
You must conduct the following service measures every 100 operating hours:
• Replace engine oil.
• Check the sparking plug, clean if necessary / set the electrode gap of the sparking plug
You must conduct the following service measures every 200 operating hours:
• Replace the sparking plug
• Replace
air
¿
lter
(The following service work should be executed by an authorised dealer, HURST directly or
the engine manufacturer.)
You must conduct the following service measures every 300 operating hours:
• Replace the sparking plug and the
¿
lter element
• Clean and adjust the carburettor, valve clearance, valve seat and cylinder head.
You must conduct the following service measures every 1000 operating hours or every
2 years:
• Check the starter
• Inspect the engine for damage
• Check the fuel line and replace, if necessary.
11.3 Additional service work