INSTALLATION
38
Unframed Specialty Shapes
Unframed specialty shape shutters are always inside mounted and attached with magnets.
NOTE:
If a Decorative Sill Cover was ordered, refer to page 39.
1.
Place the shaped panel in the opening and center it.
2.
Mark the position of the left and right edges of the shape on the bottom of the opening.
3.
Measure in from each mark
1
/
2
", and make another mark. The second marks indicate where
the outside edges of the magnets will be installed.
4.
At the second set of marks, measure and
mark 1
3
/
8
" back from the front edge of
the opening. The front of the magnet will
be located here.
➤
Measure for magnet position at the
top center of the shape in the same
way.
➤
If more than three magnets are
provided, space them evenly in
the opening.
5.
Attach all magnets to the opening using the supplied magnet screws.
6.
Attach strike plates to the shape so that they will align with the magnets when the shaped
panel is installed.
7.
Install the unframed specialty shape panel and center from side to side.
➤
Check that each magnet makes good contact with the strike plates.
➤
Make any necessary adjustments to magnets that do not hold securely.
8.
Perform any necessary finish work to complete the installation (see page 42).
Unframed Specialty Shapes
Left Edge
of Shape
Measure in
½
"
½
"
Magnet
Glass
Specialty Shape
Shutter Panel
Strike
Plate
1
3
/
8
"