Hunter X-CORE XC-2 Скачать руководство пользователя страница 2

2

 

 

https://hunter.help/

XCore

Table of Contents

X-Core Components

SEASONAL ADJUSTMENT

WATER DAYS

START TIMES

SYSTEM OFF

CURRENT TIME/DAY

RUN TIMES

ACTIVE

SENSOR BYPASS

RUN

MANUAL-ONE STATION

Start Time Symbol

Sprinkler Off Days

Station Number

Odd/Even/Interval Days

Program Indicator

Active Water Day

Month Symbol

Non-Active Water Day

Run Time Symbol

Day of Week

Seasonal Adjust (%)

Rain Sensor Active/Bypass

Station Running

Day Symbol

② ③

⑫ ⑬

⑤ ⑥ ➐

Control Buttons

Sensor Bypass Switch

X-Core Components .........................................................................2
Setting the Current Date and Time ..................................................3
Setting a Program Start Time ..........................................................3
Eliminating a Program Start Time ....................................................3
Setting a Station Run Time ..............................................................3
Setting Water Days ......................................................................... 4
Selecting Odd or Even Days to Water.............................................. 4
Selecting Interval Watering ............................................................ 4
Seasonal Adjust ............................................................................... 4
Manual Single Station ..................................................................... 4
Manual Program ............................................................................. 4
One-Touch Manual Start and Advance............................................ 4
Test Program ....................................................................................5
System Off ........................................................................................5
Programmable Rain Off ...................................................................5
Sensor Bypass  .................................................................................5
Full Reset  .........................................................................................5
Troubleshooting .............................................................................. 6
Hidden Features ...............................................................................7
Compliance Information .................................................................. 8

Содержание X-CORE XC-2

Страница 1: ...RT GUIDE X Core Irrigation Controller Programming Guide SEASONAL ADJUSTMENT WATER DAYS START TIMES SYSTEM OFF CURRENT TIME DAY RUN TIMES ACTIVE SENSOR BYPASS RUN MANUAL ONE STATION https hunter help XCore SCAN for help ...

Страница 2: ...just Rain Sensor Active Bypass Station Running Day Symbol Control Buttons Sensor Bypass Switch X Core Components 2 Setting the Current Date and Time 3 Setting a Program Start Time 3 Eliminating a Program Start Time 3 Setting a Station Run Time 3 Setting Water Days 4 Selecting Odd or Even Days to Water 4 Selecting Interval Watering 4 Seasonal Adjust 4 Manual Single Station 4 Manual Program 4 One To...

Страница 3: ...MPORTANT The controller dial must be in RUN position to enable automatic irrigation SETTING A PROGRAM START TIME 1 Turn the dial to the START TIMES position 2 Use the PRG button to select program A B or C 3 Use the and buttons to change the Start Time The Start Time advances in 15 minute increments 4 Press the button to add another Start Time or PRG button to set a Start Time for the next program ...

Страница 4: ...EASONAL ADJUST Changes all run times by a percentage for local conditions Press or to change from 10 to 150 of original run times MANUAL SINGLE STATION 1 Turn dial to Manual Single Station position 2 Press to select station Use or to set manual run time 3 Turn dial to RUN position to begin immediately MANUAL PROGRAM 1 Turn dial to RUN position 2 Press and hold button for three seconds 3 Press PRG ...

Страница 5: ... OFF wait until OFF stops blinking then turn dial back to RUN SENSOR BYPASS Overrides sensor shutdown to allow watering 1 Move sensor BYPASS switch to BYPASS position 2 Return switch to ACTIVE to allow sensor shutdown SCHEDULING TIPS A program is a watering schedule that includes Start Time s Run Time s and Water Day s A Start Time is the time of day the Stations in the Program start watering A Ru...

Страница 6: ...t controller has been wired correctly Wire from SmartPort Attach wire to Red 24 VAC AC terminal 1 White 24 VAC AC terminal 2 Blue Remote terminal REM DISPLAY SHOWS WATERING BUT NO WATERING IS OCCURRING Problem in field wiring Problem with solenoids No water pressure to system Check field wiring voltmeter Check valve solenoid s Verify water source to open FROZEN OR GARBLED DISPLAY Power surge occur...

Страница 7: ...stment changes from being made by Solar Sync for up to 99 days Use the to increase decrease the number of days the delay should run HIDE PROGRAMS Hold and turn to WATER DAYS Use to change from 4 to 1 to hide extra programs Option 1 will show only program A Start Time 1 Option 4 will show all programs and Start Times CLIK DELAY Hold and turn to OFF Set number of days for watering to remain off afte...

Страница 8: ...tative of Hunter Industries Inc or an experienced radio television technician for additional suggestions The following statement is applicable when irrigation controller is used with accessory Wi Fi device To satisfy FCC RF Exposure requirements for mobile and base station transmission devices a separation distance of 20 cm or more should be maintained between the antenna of this device and person...