Built on Innovation
®
7
Hidden Features
Feature
Where Found
Description
PROGRAMMABLE
SENSOR OVERRIDE
Hold
–
and turn to
START TIMES.
Sets individual stations to ignore sensor shutdowns. Select stations with
◄ or ►, (use
+
/
–
) to change to
OFF
to ignore sensor.
CYCLE AND SOAK
Hold
+
and turn to
RUN TIMES
.
Enter Cycle, press
PRG
to set
Soak.
Sets max time a station can run at once, and minimum time it must wait
before another cycle. Divides run time into segments to prevent runoff.
DELAY BETWEEN
STATIONS
Hold
–
and turn to
RUN TIMES.
Inserts a delay (seconds or minutes) between stations in a run time, for
slow valves or recharging tanks.
SOLAR SYNC® DELAY
Hold
–
and turn to
SOLAR SYNC.
Allows the user to postpone seasonal adjustment changes from being
made by Solar Sync for up to 99 days. Use the
+
/
–
to increase/decrease
the number of days the delay should run.
HIDE PROGRAMS
Hold
–
and turn to
WATER DAYS.
Use
+
/
–
to change from 4 to 1 to hide extra programs. Option 1 will show
only program A, Start Time 1. Option 4 will show all programs and
Start Times.
CLIK-DELAY
Hold
+
and turn to
OFF.
Set number of days for watering to remain off, after sensor has been
activated and restored.
TOTAL RUN TIME
Turn to
RUN TIMES
. Press ◄
when station 1 is shown,
PRG
to
select other programs.
Calculates and displays total of all run times in a program Start Time.
EASY RETRIEVE®
Hold
+
and
PRG
to Save. Hold
–
and
PRG
to Restore.
Saves all program information to restore at a later time.
TOTAL RESET
Hold
PRG
and press
RESET
button.
Returns to factory defaults and erases watering schedule and settings.
QUICKCHECK™
+
,
–
, ◄, ► together, then
+.
Checks all stations for wiring problems.