With the flange compartment lid removed and prior to disassembly, take time to note the orientation of the various
components within the flange compartment (fig 128). This will be valuable later for reference during final assembly. In
particular notice:
• How the solenoid wires fold over the top and to the flat side of the solenoid
• How, in the Auto position, the flat on the side of the solenoid faces to the outside
• How the pilot valve’s fittings and connected tubing point in a specific direction
• How the pressure regulator is tucked into position within the compartment
Selector cap Removal
the selector cap turns the solenoid when the user changes the on-auto-oFF settings. under normal operating
conditions, the selector cap should not need replacement. the selector cap can become damaged if the incorrect
tool is used to make on-auto-oFF selection adjustments. prior to removing the selector cap, notice that the
solenoid wires run over the top of the solenoid and out of the selector cap on the side of the solenoid that has the
flat surface. Also note that the Solenoid wires are positioned side-by-side and not twisted. To remove the Selector
cap, simply lift it up and away from the solenoid (fig 129).
FIg 128
FIg 129
Fig 127
Fig 128
42
Содержание G835
Страница 2: ......
Страница 21: ...Fig 47 Fig 49 Fig 50 Fig 48 Fig 48 Fig 47 Fig 48 Fig 47 18...
Страница 57: ...54...