30
Caution
Relay contact can stand up to 24V/1A. In case that it is connected to the external circuit
which is over 24V/1A, it can cause a problem on the system.
INTENSIVE RECODING
When alarm is triggered, system instantly assigns “remaining fps” to alarm-triggered channel and
increases recording speed during the selected dwell time, and also will trigger alarm signal via the
selected sensor-out channel. The recording speed of all other channel will remain unchanged.
PRESET
User can select the camera to move to preset position, once the sensor is triggered. (User should setup
preset position in PTZ menu 3.2.6 in advance)
DWELL (Post Alarm)
Set the recording period from the start of sensor input activation. During this period, the corresponding
camera image will record according to the frame and alarm (relay) output set. The recording stops and
alarm output is turned off when the setting period is elapsed.
PRE-ALARM
Set recording period in seconds just before perceiving sensor input.
The system records in certain seconds of time prior to the time that alarm is activated, so that user can
search video even before alarm is triggered. The pre-alarm recording mode is always “continuous” at
the recording speed that user sets in “record” of “camera” menu.