Corrective action
Explanation
State name
State code
Transient – No action is necessary.
Router is in boot phase and is
waiting for indirect and direct
management packets.
Waiting for MIPs in Boot
8
Transient – No action is necessary.
Router is in boot phase and is
downloading commissioning
software.
Downloading
Commissioning
Software
9
Installer must complete validation.
Router is waiting for antenna
pointing validation to complete.
Occurs during installation only.
Waiting for Antenna
Pointing Complete
10
Installation – Commissioning phase
Transient – No action is necessary.
Router is starting up in
commissioning phase.
Starting Up in
Commissioning
11
Transient – No action is necessary.
Router is in commissioning phase.
Downlink has been established;
Downlink Established in
Commissioning
12
that is, beacon is being tracked and
transmission information packets
are being received.
Transient – No action is necessary.
Router is in commissioning phase
and is waiting for indirect and direct
management packets.
Waiting for MIPs in
Commissioning
13
Transient – No action is necessary.
Router is in commissioning phase.
Probing is in progress.
Occurs
during installation only.
Probing in Progress
14
Occurs during installation only.
Router is in commissioning phase.
Probing has failed.
Probing Failure
15
Transient – No action is necessary.
Router is in commissioning phase.
Router is registering with the
NOCC.
Registering ST
16
Occurs during installation only.
Router is in commissioning phase:
registration with the NOCC has
failed.
ST Registration Failure
17
Transient – No action is necessary.
Router is in commissioning phase;
router is waiting for capacity keys
from the NOCC.
Waiting for Capacity
Keys
18
Transient – No action is necessary.
Router is in commissioning phase;
router is reconciling profiles with
the NOCC.
Reconciling Profiles in
Commissioning
19
Transient – No action is necessary.
Router is in commissioning phase
and is downloading operational
software.
Downloading
Operational Software
20
Note:
State codes 1 – 20 appear only while the router is being installed or during a hard reboot (resulting
from power being removed and then restored).
Operational phase
HN9500 Satellite Router User Guide
36
1037737-0001 Revision E
System Control Center
Chapter 2