![Hughes HN9500 Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/hughes/hn9500/hn9500_installation-manual_2182047056.webp)
A quick look at the validation procedure
This section summarizes how you use the OVT to evaluate the performance and quality of a
newly installed HN9500 site. For detailed information on the OVT, see
Installer’s Guide to the
Ka-Band Onsite Validation Tool (OVT)
(1038091-0001).
The basic validation steps are:
1.
With your installer laptop computer connected to the router, use Internet Explorer to access
and log onto the HughesNet Installation Portal.
Specific steps for accessing the Portal are explained later.
2.
Click the
Onsite Validation Tool
link.
3.
Enter SAN and FSO numbers from the Installation Reference Sheet to identify the site.
4.
A subsequent screen shows the latest and target values for selected performance parameters
for the site, as shown in
Figure 22: Latest values compared to target values (partial screen)
on page 42.
If all target values for the performance parameters are met
(all difference values
are green), click the
Sign Off
button (not shown in this figure) and record the sign-off code.
If the first screen after login shows that the site met the target values and you obtained the
sign-off code, validation is complete. If any target values were not met, as indicated by a red
difference value, continue.
Figure 22: Latest values compared to target values (partial screen)
5.
If target values are not met,
follow the recommended actions displayed by the OVT.
Examples of recommended actions are
Check line of sight to the satellite
or
Replace IDU
.
6.
For each recommended action (they are displayed in succession, as appropriate), click the
Checked
or
Repaired
button.
Depending on results, the OVT may display additional recommended actions.
7.
When the target values are met (all difference values are green), click the
Sign Off
button
and record the sign-off code.
The site performance and installation quality are validated when all target values have been met
and you have obtained the sign-off code.
For validation procedure details, see the
Installer’s Guide to the Ka-Band Onsite Validation
Tool (OVT)
(1038091-0001).
Prerequisites
The following are prerequisites for using the OVT to validate site installation:
• Physical installation of the router, antenna, and IFL cables must be complete.
HN9500 Satellite Router Installation Guide
42
1037736-0001 Revision G
Validating the installation
Chapter 6
Содержание HN9500
Страница 1: ...1037736 0001 Revision G February 26 2010 HN9500 Satellite Router Installation Guide ...
Страница 10: ......
Страница 14: ......
Страница 20: ......
Страница 40: ......
Страница 70: ......
Страница 78: ......
Страница 110: ......
Страница 120: ......
Страница 132: ......
Страница 136: ...HN9500 Satellite Router Installation Guide 122 1037736 0001 Revision G Index ...