2008 by Huchez Treuils S.A.S.
Original manual
15
FR
Reproduction prohibited
IRREGULARITY
OBSERVED
(result)
POSSIBLE CAUSE
(result)
WHAT TO DO?
(result)
Short-circuit
The contact B has melted on the control box
Replace the 3-button control box
Burned out diode
Replace the diode paying attention to
the poles
Short-circuit at the rectifier on the motor side
Replace the rectifier paying attention
to the poles
Burned out D-type resistor
Replace the resistor
Presence of excess carbon powder on the
carbon brush holders
Disassemble the winch and clean the
carbon powder
Burned out motor
Replace motor
Circuit board damaged due to winding of the
cable
Replace the circuit board
The winch fails to
lift the nominal load
Overload
Reduce the load
Short circuit of the circuit breaker / switch
located in the centre of the armature or parts of
the winding burned out
Replace the switch located in the
centre of the frame
Burned out parts in the winding part of the
winch
Replace the winding part of the winch
Wrong carbon brush model or too short model
Replace the carbon brush
Burned out or deformed carbon brush holder
Replace the carbon brush holder
13 – Annexes
A – Optional equipment.
B – Spare parts.
C –Electrical diagram
D – Maintenance log.
Содержание PALANBOX 160
Страница 17: ...2008 by Huchez Treuils S A S Original manual 17FR Reproduction prohibited B Spare parts PALANBOX 80 kg...
Страница 19: ...2008 by Huchez Treuils S A S Original manual 19FR Reproduction prohibited PALANBOX 160 kg...
Страница 21: ...2008 by Huchez Treuils S A S Original manual 21FR Reproduction prohibited PALANBOX 230 kg...
Страница 25: ...2010 by Huchez Treuils S A S Original manual 25FR Reproduction prohibited...