The 

HELP

 push button on each RED ALERT

®

 camera telephone can be programmed to dial three 

different telephone numbers.  These include a primary telephone number and two 

rollover

 telephone 

numbers.  The emergency telephone will automatically dial the first rollover number if the emergency call 
cannot connect to the primary telephone number (i.e., a busy signal or no answer).  The telephone 
automatically dials the second rollover telephone number if the first rollover number is busy or is not 
answered. 

Each RED ALERT

®

 camera telephone can provide two isolated control outputs in the form of a dry (volt-

free) contact closure rated at 125 mA.  One output is controlled by the telephone’s emergency call 
activation and the other is remotely controlled by a called party DTMF activation code. 

The telephone component in all RED ALERT

®

 camera telephones is line-powered and requires a 

minimum line current of 24 mA for proper operation.  These telephones can be connected to any of the 
following networks: 

 

C.O. (Central Office) line to the PSTN (Public Switched Telephone Network) 

 

24 V dc or 48 V dc analog station port of a PBX (Private Branch Exchange), PABX (Private 
Automatic Branch Exchange), or KSU (Key Service Unit). 

N

OTE

:

  Connection to pay telephone extensions or shared service (party) lines must be avoided. 

The CCD camera within all RED ALERT

®

 camera telephones requires a 12 V dc power source. 

N

OTE

:

  The operating temperature range of the camera is 14 ºF to 122 ºF (−10 ºC to 50 ºC).  The 

telephone itself has an operating range of −4 ºF to 140 ºF (−20 ºC to 60 ºC). 

RED ALERT

®

 camera telephones provide the flexibility to address a diverse range of applications.  A 

wide variety of functions can be achieved by altering the configuration data stored in the telephone’s non-
volatile memory.  These configuration options include: 

 

pre-programmed auto-dial telephone numbers 

 

call termination method (automatic or manual) 

 

maximum call duration 

 

answering options 

Values for these functions are initially programmed during factory testing.  The settings can be changed 
remotely from a touch-tone telephone, locally (with an integral or portable keypad), or via TMA.  
Emergency auto-dial telephone numbers are typically programmed in accordance with existing security 
plans.  Most applications will require very little additional programming because the factory defaults 
should be applicable to most installations. 

Models

 

The following RED ALERT

®

 camera telephone models are detailed in this manual: 

Table 1.  Model Chart 

Model 

Description 

393-001CAM 

Surface-Mount Emergency Telephone

 housed in a glass-reinforced polyester 

enclosure; includes a 

HELP

 autodial push button. 

Содержание GAI-TRONICS RED ALERT 393-001CAM

Страница 1: ...Emergency Call Operation 4 Non Emergency Call Operation 4 Receiving a Call 5 Disconnecting a Call 5 Location Identification 5 Installation 5 Safety Guidelines 6 General Installation Guidelines 6 Locat...

Страница 2: ...Sequences 18 Dialing Methods 19 Password Protection 21 Auto Answer Alert 21 Off Hook Ringing 21 Disconnect Options 22 ADA Americans with Disabilities Act Programming 23 Extended Strobe Operation Requ...

Страница 3: ...s and report problems when used with TMA Telephone Management Application software Using TMA with RED ALERT telephones reduces system test and maintenance time and decreases liability issues associate...

Страница 4: ...vate Automatic Branch Exchange or KSU Key Service Unit NOTE Connection to pay telephone extensions or shared service party lines must be avoided The CCD camera within all RED ALERT camera telephones r...

Страница 5: ...package Model 12509 042 includes a single line transceiver for polling a single telephone at a time Each telephone requires approximately 90 seconds to relay its health status to TMA Use multiple tran...

Страница 6: ...steadily when the called party acknowledges receiving the call by transmitting a DTMF or after answering the call 2 Two way hands free conversation can now occur Non Emergency Call Operation Applicab...

Страница 7: ...oice calls call progress tones i e busy signal fast busy or reorder tone and when enabled dial tone Refer to the Disconnect Options section of this manual for factory defaults and available options Lo...

Страница 8: ...in the enclosure supplied with the phone Do not install telephone jacks in wet locations unless the jack is specifically designed for wet locations Do not touch uninsulated telephone wires or terminal...

Страница 9: ...ssible Sealed fittings should be installed at all cable entry points Silicone sealant or equivalent should be applied around and inside all conduit entries to prevent moisture ingress Refer to the exa...

Страница 10: ...6 Pull the telephone line through the conduit and into the enclosure 7 Connect the telephone line to the customer supplied telephone line surge suppressor if applicable and modular jack USOC RJ11 or...

Страница 11: ...4 467D Camera Telephone Manual Page 9 of 30 P Standard IOMs Current Release 42004 Instr Manuals 42004 467D docx 04 19 Figure 6 Model 394AL 001CAM Figure 7 Model 393 001CAM and 394AL 001CAM Component L...

Страница 12: ...e entry hole in the back box 3 Install the telephone line and cable fitting NOTE Telephone line connections directly to terminal block TB1 are acceptable 4 If using the modular jack 1 Remove the cover...

Страница 13: ...levels if necessary see Figure 12 for speaker volume and microphone sensitivity potentiometer locations 3 Perform the initial programming see the Programming section 10 Verify operation by calling to...

Страница 14: ...shown below Figure 11 Model 398 001CAM is shown as an example Connection to optional GAI Tronics 530 001 540 001 531A Strobe Hardware Configuration The hardware configuration options are explained in...

Страница 15: ...f the telephone via polling with SMART operation enabled When the auto answer feature is enabled the telephone automatically answers the call and attempts to communicate with TMA If the caller is not...

Страница 16: ...High Gain Selected jumper J17 in position HI Password Enable Disable Factory Setting Password enabled This telephone can be configured to enable or disable the password protection for programming stan...

Страница 17: ...ommand if the beep is not initially received NOTE This feature requires the use of GAI Tronics No 40404 045 plug in power supply 120 V ac source required Output four connects to terminal block TB5 on...

Страница 18: ...ods to program RED ALERT emergency telephones Standard Mode and SMART Mode Standard mode programming is used if the telephone system installation does not include TMA PC software SMART mode programmin...

Страница 19: ...de only the HELP push button Move the switch harness plug from the HELP connector J7 to the CALL push button connector J1 on the telephone PCBA 3 Press the CALL or HELP push button whichever is connec...

Страница 20: ...remote access programming Follow these directions to configure the telephone to the desired operating parameters 1 Connect to the telephone locally see the Local Access Programming section or remotely...

Страница 21: ...the primary telephone number i e a busy signal or no answer The emergency telephone automatically dials the second rollover number if configured if the emergency call cannot connect to first rollover...

Страница 22: ...ce ends in 3 instead of 1 None CALL or ASSISTANCE Button Auto dial DD 4 DD 5 DD 6 Same as HELP Button Auto dial Number 1 except the sequence end digits NOTE The 5 and 6 telephone numbers are used only...

Страница 23: ...t password must be supplied to remotely program the telephone If the password has been changed and programming mode can t be accessed see Password Disabled Programming section Example To program the p...

Страница 24: ...7 Disconnect Options Feature Key Sequence Description Default HELP Push button Disconnect Option 1 7 L The HELP push button cannot be used to disconnect a call for 10 seconds after initially pressing...

Страница 25: ...e enables security personnel to quickly and easily locate an individual in trouble DTMF Call Disconnect Enables the security operator to disconnect the call by pressing Table 8 ADA Programming Feature...

Страница 26: ...6 as the control sequence enter 7 2 6 8 90125 Duration of Timed Activation 2 6 N N N Sets the duration of the activation of the Output 4 contact when triggered by the control sequence Use entries 001...

Страница 27: ...e activation within 1 second of dial sequence completion No Early Microphone Option Disable 7 1 0 Returns telephone to default operation of microphone Yes SMART Mode Programming TMA software is design...

Страница 28: ...wn Operation 1 None Password Protection Feature Programming see Table 4 Password Protection 14NNNN 2468 Disconnect Options Programming see Table 7 Emergency Push button Disconnect 17L 1 enabled Call T...

Страница 29: ...performed on a regular basis or when corrosion is first noticed on your Model 397 001CAM or 398 001CAM camera telephone Cleaning For the camera provided inside the telephone periodic cleaning of the c...

Страница 30: ...rews Torx T 25 1 inches Pack of 10 12520 009 Push Button Replacement Kit HELP 12520 010 Push Button Replacement Kit CALL ASSISTANCE 12521 004 Microphone Replacement Kit 12522 007 Piezo Speaker Replace...

Страница 31: ...l 398 001CAM only chrome plated zinc Dimensions Front panel 12 00 H 10 00 W in 305 254 mm Back box overall 10 06 H 8 43 W 2 50 D in 256 214 63 5 mm Cutout for mounting back box 10 13 H 7 63 W in 257 1...

Страница 32: ...The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities o...

Отзывы: