background image

Pub. 42004-467D 

Camera Telephone Manual 

Page 22 of 30 

P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-467D.docx 

04/19 

Table 6.  Off-Hook Ringing 

Feature 

Key 
Sequence 

Description 

Default 

Off-Hook 
Ringing 

# 2 2 

L

 

Enabling the 

off-hook ringing 

feature allows a person to 

call the telephone and have the telephone function as a 
normal telephone.  The telephone will ring after the 
splash tone is heard in the receiver if remote 
programming is not commenced within 7 seconds of the 
splash tone. 

To enable the ringing feature (enable splash tone and 
ringing), 

L

=1.  To disable the ringing feature (only splash 

tone on the phone), 

L

=

0

N

OTE

:

  Answering a call by pressing the 

C

ALL

 push 

button is only available on phones equipped with 
a CALL push button. 

0 (Disabled) 

 

Disconnect Options 

Several options are available for disconnecting a call.  Any combination of disconnect options may be 
used.  Select the method that best suits the application and follow the appropriate programming 
directions. 

Table 7.  Disconnect Options 

Feature 

Key 
Sequence 

Description 

Default 

HELP Push-
button 
Disconnect 
Option 

#  1  7  

L

 

The 

HELP

 push button cannot be used to disconnect a 

call for 10 seconds after initially pressing the push button.  
However, the HELP push button can be used to 
disconnect calls after the 10-second push button lockout 
period elapses when 

L

=1.  To prevent the 

HELP

 push 

button from disconnecting the call, set 

L

=0. 

Example

:  To enable the 

HELP

 push button disconnect, 

enter 

# 1 7 1

To disable the 

HELP

 push button disconnect, enter 

# 1 7 

0

1 (Enabled) 

Call Time-out 
Disconnect 
Option 

# 1 2 

N N

 

This feature programs the maximum length of a call if no 
other disconnect features are used.  The valid entries are 
1–99, representing 1-minute increments and 0 
representing 4.5 hours.  The call duration timer begins 
when the emergency telephone goes off-hook.  The 
telephone automatically disconnects after the 
programmed time-out period elapses. 

The user can immediately press the 

HELP

 button to 

reconnect the autodial number.  This feature helps 
prevent non-emergency calls from tying up emergency 
lines for long lengths of time. 

Example

:  To make the maximum call length 2 minutes,  

enter 

# 1 2 0 2

10 
(10  minutes) 

Содержание GAI-TRONICS RED ALERT 393-001CAM

Страница 1: ...Emergency Call Operation 4 Non Emergency Call Operation 4 Receiving a Call 5 Disconnecting a Call 5 Location Identification 5 Installation 5 Safety Guidelines 6 General Installation Guidelines 6 Locat...

Страница 2: ...Sequences 18 Dialing Methods 19 Password Protection 21 Auto Answer Alert 21 Off Hook Ringing 21 Disconnect Options 22 ADA Americans with Disabilities Act Programming 23 Extended Strobe Operation Requ...

Страница 3: ...s and report problems when used with TMA Telephone Management Application software Using TMA with RED ALERT telephones reduces system test and maintenance time and decreases liability issues associate...

Страница 4: ...vate Automatic Branch Exchange or KSU Key Service Unit NOTE Connection to pay telephone extensions or shared service party lines must be avoided The CCD camera within all RED ALERT camera telephones r...

Страница 5: ...package Model 12509 042 includes a single line transceiver for polling a single telephone at a time Each telephone requires approximately 90 seconds to relay its health status to TMA Use multiple tran...

Страница 6: ...steadily when the called party acknowledges receiving the call by transmitting a DTMF or after answering the call 2 Two way hands free conversation can now occur Non Emergency Call Operation Applicab...

Страница 7: ...oice calls call progress tones i e busy signal fast busy or reorder tone and when enabled dial tone Refer to the Disconnect Options section of this manual for factory defaults and available options Lo...

Страница 8: ...in the enclosure supplied with the phone Do not install telephone jacks in wet locations unless the jack is specifically designed for wet locations Do not touch uninsulated telephone wires or terminal...

Страница 9: ...ssible Sealed fittings should be installed at all cable entry points Silicone sealant or equivalent should be applied around and inside all conduit entries to prevent moisture ingress Refer to the exa...

Страница 10: ...6 Pull the telephone line through the conduit and into the enclosure 7 Connect the telephone line to the customer supplied telephone line surge suppressor if applicable and modular jack USOC RJ11 or...

Страница 11: ...4 467D Camera Telephone Manual Page 9 of 30 P Standard IOMs Current Release 42004 Instr Manuals 42004 467D docx 04 19 Figure 6 Model 394AL 001CAM Figure 7 Model 393 001CAM and 394AL 001CAM Component L...

Страница 12: ...e entry hole in the back box 3 Install the telephone line and cable fitting NOTE Telephone line connections directly to terminal block TB1 are acceptable 4 If using the modular jack 1 Remove the cover...

Страница 13: ...levels if necessary see Figure 12 for speaker volume and microphone sensitivity potentiometer locations 3 Perform the initial programming see the Programming section 10 Verify operation by calling to...

Страница 14: ...shown below Figure 11 Model 398 001CAM is shown as an example Connection to optional GAI Tronics 530 001 540 001 531A Strobe Hardware Configuration The hardware configuration options are explained in...

Страница 15: ...f the telephone via polling with SMART operation enabled When the auto answer feature is enabled the telephone automatically answers the call and attempts to communicate with TMA If the caller is not...

Страница 16: ...High Gain Selected jumper J17 in position HI Password Enable Disable Factory Setting Password enabled This telephone can be configured to enable or disable the password protection for programming stan...

Страница 17: ...ommand if the beep is not initially received NOTE This feature requires the use of GAI Tronics No 40404 045 plug in power supply 120 V ac source required Output four connects to terminal block TB5 on...

Страница 18: ...ods to program RED ALERT emergency telephones Standard Mode and SMART Mode Standard mode programming is used if the telephone system installation does not include TMA PC software SMART mode programmin...

Страница 19: ...de only the HELP push button Move the switch harness plug from the HELP connector J7 to the CALL push button connector J1 on the telephone PCBA 3 Press the CALL or HELP push button whichever is connec...

Страница 20: ...remote access programming Follow these directions to configure the telephone to the desired operating parameters 1 Connect to the telephone locally see the Local Access Programming section or remotely...

Страница 21: ...the primary telephone number i e a busy signal or no answer The emergency telephone automatically dials the second rollover number if configured if the emergency call cannot connect to first rollover...

Страница 22: ...ce ends in 3 instead of 1 None CALL or ASSISTANCE Button Auto dial DD 4 DD 5 DD 6 Same as HELP Button Auto dial Number 1 except the sequence end digits NOTE The 5 and 6 telephone numbers are used only...

Страница 23: ...t password must be supplied to remotely program the telephone If the password has been changed and programming mode can t be accessed see Password Disabled Programming section Example To program the p...

Страница 24: ...7 Disconnect Options Feature Key Sequence Description Default HELP Push button Disconnect Option 1 7 L The HELP push button cannot be used to disconnect a call for 10 seconds after initially pressing...

Страница 25: ...e enables security personnel to quickly and easily locate an individual in trouble DTMF Call Disconnect Enables the security operator to disconnect the call by pressing Table 8 ADA Programming Feature...

Страница 26: ...6 as the control sequence enter 7 2 6 8 90125 Duration of Timed Activation 2 6 N N N Sets the duration of the activation of the Output 4 contact when triggered by the control sequence Use entries 001...

Страница 27: ...e activation within 1 second of dial sequence completion No Early Microphone Option Disable 7 1 0 Returns telephone to default operation of microphone Yes SMART Mode Programming TMA software is design...

Страница 28: ...wn Operation 1 None Password Protection Feature Programming see Table 4 Password Protection 14NNNN 2468 Disconnect Options Programming see Table 7 Emergency Push button Disconnect 17L 1 enabled Call T...

Страница 29: ...performed on a regular basis or when corrosion is first noticed on your Model 397 001CAM or 398 001CAM camera telephone Cleaning For the camera provided inside the telephone periodic cleaning of the c...

Страница 30: ...rews Torx T 25 1 inches Pack of 10 12520 009 Push Button Replacement Kit HELP 12520 010 Push Button Replacement Kit CALL ASSISTANCE 12521 004 Microphone Replacement Kit 12522 007 Piezo Speaker Replace...

Страница 31: ...l 398 001CAM only chrome plated zinc Dimensions Front panel 12 00 H 10 00 W in 305 254 mm Back box overall 10 06 H 8 43 W 2 50 D in 256 214 63 5 mm Cutout for mounting back box 10 13 H 7 63 W in 257 1...

Страница 32: ...The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities o...