Pub. 42004-467D
Camera Telephone Manual
Page 16 of 30
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-467D.docx
04/19
The output pulse duration (closure) and the DTMF code used for the
open gate
command are user
programmable (see the Output Four Control section).
TMA can be used to change the contact closure settings if the RED ALERT
®
telephone is operating in
SMART mode.
Hardware Settings
Table 2. Hardware Settings Table
Function
Default Settings
User Settings
Setting
Jumper/Position
Setting
Jumper/Position
Auto-answer
Enabled
J14/EN
Password Protection
Enabled
J9/EN
Line Polarity
Non-polarized
J6/NON
Command Select
Auto
J20/AUTO
DTMF Gain Select
Low Gain
J17/LO
Low-Power Mode
Disabled
J21, J22, J23 not
installed
Programming
Read this entire section and record the desired key sequences in Table 12 before programming the RED
ALERT
®
camera telephone.
There are two methods to program RED ALERT
®
emergency telephones;
Standard Mode
and
SMART
Mode
. Standard mode programming is used if the telephone system installation does not include TMA
PC software. SMART mode programming should be used with TMA installed and the telephones should
be configured for monitoring. Normal telephone operation is identical for both modes of operation.
Each RED ALERT
®
camera telephone is factory-programmed to receive standard mode commands (see
Table 12 for the factory-default settings).
Password Disabled Programming
The programmable features of the RED ALERT
®
camera telephones are protected by a factory default or
user specified password. A telephone may need to be configured for password disabled programming if
the password has been changed from the default and has been forgotten or is unknown.
To configure a RED ALERT
®
camera telephone for password disabled programming:
1.
Access the telephone’s PCBA and disable the password protection feature by moving jumper
J9
to
the
DIS
position.
2.
Confirm the auto-answer feature is enabled (jumper
J14
must be in the
EN
position).