Pub. 42004-501C
Division 2 VoIP Telephones
—Wired and WiFi
Page 9 of 22
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-501C.docx
03/20
Enclosure Mounting and Cable Entries
The mounting location must be flat
and provide proper clearance,
rigidity, and strength to support the
enclosure and all contained devices.
1.
Mount the enclosure using the
four 0.437-inch (11 mm)
diameter holes located on the
mounting flanges with 3/8-inch
(M8) hardware (see Figure 5).
•
The suggested mounting
height for all station
enclosures is 48 inches
(1219 mm) to the center of
the bottom mounting holes
of the enclosure.
•
telephone are not supplied
with conduit or cable
openings.
2.
Remove the front panel.
3.
Drill or punch entry openings in
the rear section of the enclosure
(see Figure 5).
•
The station is suitable for
bottom entry.
•
There must be a minimum
of ½ inch (13 mm) of
material between entry
holes.
Front Cover Removal
1.
Remove the four screws from the front panel.
2.
Turn the front panel to the right to expose the interior of the telephone enclosure.
Keep all wiring connected (see Figure 6).
3.
Hang the front panel on the front door with a small piece of wire through a mounting hole on the
panel.
Figure 5. Mounting Details