Figure 6. Installation and Maintenance Configuration
Field Wiring
1.
For wired versions:
plug the incoming Category 5 data line into the RJ45 jack, located on the
underside of the VoIP circuit PCBA (see Figure 6 and Figure 7).
2.
ac and dc powered models:
1.
Remove the two screws from the power supply cover located in the rear enclosure and remove the
power supply cover.
2.
Connect the incoming power conductors to the 3-point terminal block in the rear enclosure (see
the Local Power section).
3.
Reattach the power supply cover using the two screws previously removed from the cover.
3.
Route the speaker connection wire on the left side of the power supply to the
P4
speaker plug on the
amplifier PCBA located on the front cover.
4.
Terminate the wires per the PCBA silk screen text.
5.
Install all additional connections as indicated in the following subsections (see Table 3, Figure 6, and
Figure 7).