HUAWEI VP9050 Executive Video Terminal
User Guide
13 Maintenance and Troubleshooting
Issue 03 (2011-12-10)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
90
If a remote loopback test is performed, data is transmitted from the local site to a remote site,
and then back to the local site. Table 13-4 shows the available loopback tests on the terminal
and their objectives.
To enable the terminal to communicate with other terminals properly, the loopback test
must be stopped.
A remote video loopback test cannot be performed during a dual-stream conference.
Table 13-4
Loopback tests
Test
Item to Be
Tested/Objective
Signal Stream
Local audio
loopback
Local audio module
Microphone → 1 → 2 → speaker
Local video
loopback
Local video module
Camera → 3 → 4 → display
Remote audio
loopback
Remote audio module
Network transmission
Microphone → 1 → 5 → 6 → 7 → 8 →
6 → 5 → 2 → speaker
Remote video
loopback
Remote video module
Network transmission
Camera → 3 → 5 → 6 → 9 → 10 → 6
→ 5 → 4 → display
Network Test
Table 13-5
Network test
Test
Item to Be
Tested/Objective
Signal Stream
Network test
IP access
Terminal → LAN
or public network
Before a test, ensure that the terminal is connected to an IP network properly, the indicator of
the LAN network interface turns green, and the IP parameters are set correctly.
In
IP address
, enter an IP address. Ensure that the IP address entered and the IP address
of the terminal are in different network segments. Select
Start
. If the test is passed, the
gateway settings and the IP address of the terminal are correct.
If the terminal exists in a private network, enter an IP address in a public network in
IP
address
, and then select
Start
. If the test is passed, the gateway settings, the NAT
address, and the IP address of the terminal are correct.