Installation Reference
50/51 >>
Installing the Outdoor Optical Splitter
Route in and fix fibers.
5
Use hose clamps to fix outdoor fibers on the
appropriate hooks.
Guide the lead nylon of outdoor fibers through fiber
fixing holes, fix the lead nylon and cut off redundant part.
Fix the fiber metal jacket in the fiber routing clips.
Remove dustproof caps and insert fiber connectors into appropriate adapters
according to labels.
Port in Fiber
Distribution
Area
Interconne
cted GE
Port
Description
101
Main RTN
380H
Connected to GE receive port on the main RTN 380H
201
Connected to GE transmit port on the main RTN 380H
102
Standby
RTN 380H
Connected to GE receive port on the standby RTN 380H
202
Connected to GE transmit port on the standby RTN 380H
IN2
Customer
equipment
Connected to GE receive port on the customer equipment
IN1
Connected to GE transmit port on the customer equipment
Wrap outdoor fibers with three layers of waterproof tapes and ensure that the tapes
just fit the cable trough and the case is reliably sealed and waterproofed.
Schematic diagram of coding ports and
fibers in fiber distribution area
When wrapping outdoor fibers, do not pull waterproof tapes.
Three layers of
waterproof
tapes
Sealing
positions
Main RTN 380H
Standby RTN 380H
Customer
equipment
Close the case cover
.
6
Reliably tighten the reinforce screws to ensure waterproof effects.
4 mm hex key