Operation Manual - Security
Quidway S3000-EI Series Ethernet Switches
Chapter 2 AAA and RADIUS Protocol
Configuration
Huawei Technologies Proprietary
2-17
Table 2-21
Setting the maximum retransmitting times of stopping accounting request
Operation
Command
Set the maximum retransmitting times of
stopping accounting request
retry stop-accounting
retry-times
Restore the maximum retransmitting times of
stopping accounting request to the default
value
undo retry stop-accounting
By default, the stopping accounting request can be retransmitted for up to 500 times.
2.3.11 Setting the Supported Type of RADIUS Server
Quidway Series Switches support the standard RADIUS protocol and the extended
RADIUS service platforms, such as IP Hotel, 201+ and Portal, independently
developed by Huawei.
You can use the following command to set the supported types of RADIUS servers.
Perform the following configurations in RADIUS scheme view.
Table 2-22
Setting the supported type of RADIUS server
Operation
Command
Setting the Supported Type of
RADIUS Server
server-type
{
huawei
|
iphotel
|
portal
|
standard
}
Restore the Supported Type of
RADIUS Server to the default setting
undo server-type
By default, the newly created RADIUS scheme supports the server of
standard
type,
while the "system" RADIUS scheme created by the system supports the server of
huawei
type.
2.3.12 Setting RADIUS Server State
For the primary and second servers (no matter it is an authentication/authorization
server or accounting server), if the primary is disconnected to NAS for some fault, NAS
will automatically turn to exchange packets with the second server. However, after the
primary one recovers, NAS will not resume the communication with it at once, instead,
it continues communicating with the second one. When the second one fails to
communicate, NAS will turn to the primary one again. The following commands can be
used to set the primary server to be
active
manually, in order that NAS can
communicate with it right after the troubleshooting.
When the primary and second servers are both
active
or
block
, NAS will send the
packets to the primary server only.
Содержание Quidway S3000-EI Series
Страница 49: ...Huawei Technologies Proprietary HUAWEI Quidway S3000 EI Series Ethernet Switches Operation Manual Port ...
Страница 66: ...Huawei Technologies Proprietary HUAWEI Quidway S3000 EI Series Ethernet Switches Operation Manual VLAN ...
Страница 90: ...Huawei Technologies Proprietary HUAWEI Quidway S3000 EI Series Ethernet Switches Operation Manual Multicast ...
Страница 113: ...Huawei Technologies Proprietary HUAWEI Quidway S3000 EI Series Ethernet Switches Operation Manual QoS ACL ...
Страница 148: ...Huawei Technologies Proprietary HUAWEI Quidway S3000 EI Series Ethernet Switches Operation Manual Integrated Management ...
Страница 178: ...Huawei Technologies Proprietary HUAWEI Quidway S3000 EI Series Ethernet Switches Operation Manual STP ...
Страница 207: ...Huawei Technologies Proprietary HUAWEI Quidway S3000 EI Series Ethernet Switches Operation Manual Security ...
Страница 255: ...Huawei Technologies Proprietary HUAWEI Quidway S3000 EI Series Ethernet Switches Operation Manual Network Protocol ...
Страница 277: ...Huawei Technologies Proprietary HUAWEI Quidway S3000 EI Series Ethernet Switches Operation Manual System Management ...
Страница 377: ...Huawei Technologies Proprietary HUAWEI Quidway S3000 EI Series Ethernet Switches Operation Manual Remote Power feeding ...
Страница 389: ...Huawei Technologies Proprietary HUAWEI Quidway S3000 EI Series Ethernet Switches Operation Manual Appendix ...