Parameter
Description
Value
Synchronization
Method
Way of synchronizing data between the
primary and secondary resources.
l
Manual
: A user needs to manually
synchronize data from the primary
resource to the secondary resource.
l
Timed wait when synchronization
begins
: The system starts timing as
soon as the latest synchronization
begins. When the time specified in
Interval
has elapsed, the system
automatically starts to synchronize data
between the primary resource and
secondary resource again.
NOTE
If the latest synchronization is still being
executed after the time specified in
Interval
has elapsed, the data
synchronization will start after the latest
synchronization finishes.
l
Timed wait when synchronization
ends
: The system starts timing as soon
as the latest synchronization ends.
When the time specified in
Interval
has elapsed, the system automatically
starts to synchronize data between the
primary resource and secondary
resource again.
[Example]
Manual
NOTE
This parameter is
available only when
Replication Mode
is set
to
Asynchronous
.
Interval
Time spent waiting of the two
synchronization methods,
Timed wait
when synchronization begins
and
Timed
wait when synchronization ends
.
NOTE
This parameter is available when
Replication
Mode
is set to
Asynchronous
and
Synchronization Method
is set to
Timed wait
when synchronization begins
or
Timed wait
when synchronization ends
.
[Value range]
l
The interval is an
integer ranging
from 1 to 1440
(inclusive), when
minutes
is used as
the unit.
l
The interval is an
integer ranging
from 3 to 59
(inclusive), when
seconds
is used as
the unit.
NOTE
When the primary-end
model is 2200 V3, the
resource type is LUN,
the unit can only be
minutes
and the interval
is an integer ranging
from 15 to 1440
(inclusive).
OceanStor V3 Series
Remote Replication Feature Guide for Block
6 Managing Remote Replication
Issue 06 (2018-01-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
110