6.5.2 Outputting Original Flows
To ensure that original flows can be correctly output to the NMS, you need to configure the
aging time, output format, and source and destination addresses for original flows.
Context
IPv6 original flows can be output only in V9 format.
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
ipv6 netstream export version
9
[
origin-as
|
peer-as
] [
bgp-nexthop
]
The output format of original flows is configured.
Step 3
(Optional) Run:
ipv6 netstream export template timeout-rate
timeout-interval
The interval at which the template for outputting original flows in V9 format is refreshed.
By default, the output template of original flows is refreshed every 30 minutes.
Step 4
Run:
ipv6 netstream export source
ip-address
The source IP address is configured for aggregated flows.
Step 5
Configure the destination IP address and UDP port number of the peer NSC for NetStream
original flows in the system or slot view.
l
In the system view:
Run:
ipv6 netstream export host
ip-address
port
The destination IP address and UDP port number of the peer NSC are configured for
NetStream original flows to be output.
l
In the slot view:
1.
Run:
slot
slot-id
The view of the slot where the LPU for NetStream sampling resides is displayed.
2.
Run:
ipv6 netstream export host
ip-address
port
The destination IP address and UDP port number of the peer NSC are configured for
NetStream original flows to be output.
3.
Run:
quit
The system view is displayed.