HUAWEI MU739 HSPA+ LGA Module
Hardware Guide
Electrical and Reliability Features
Issue 01 (2011-08-24)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
56
Item
Test Condition
Standard
Salty fog test
Temperature: 35°C
Density of the NaCl solution: 5% ± 1%
Spraying interval: 8 h
Duration of exposing the module to
the temperature of 35°C: 16 h
IEC60068
Sine vibration
Frequency range: 5 Hz to 200 Hz
Acceleration: 10 m/s
2
Frequency scan rate: 1 oct/min
Test period: 3 axial directions. Five
circles for each axial direction.
IEC60068
Shock test
Half-sine wave shock
Peak acceleration: 300 m/s
2
Shock duration: 11 ms
Test period: 6 axial directions. One
shock for each axial direction.
IEC60068
Clash test
Half-sine wave
Peak acceleration: 180 m/s
2
Pulse duration: 6 ms
Repetition time: 6 directions. 1000
times for each direction.
IEC60068
Drop test
First case: 0.3 m in height. Drop the
MU739 module on the marble terrace
with one surface facing downwards
twice. Six surfaces should be tested.
Second case: 0.8 m in height. Drop
the MU739 module on the marble
terrace with one surface facing
downwards twice. Six surfaces should
be tested.
IEC60068
5.7 EMC and ESD Features
EMC tests have to be performed on the application as soon as possible to detect any
potential problems.
Special attention should be paid to the following:
Possible harmful emissions radiated by the application to the RF receiver in the
receiver band.
ESD protection is mandatory on all signals which are externally accessible
Typically, ESD protection is mandatory for the following: