Operating and Storage Temperatures
5.2 Absolute Ratings
Table 5-1 lists the absolute ratings for the module. Using the module beyond these
conditions may result in permanent damage to the module.
Table 5-1
Extreme working conditions for the MU509-65 module
Symbol Specification
Min.
Max.
Unit
VBAT
External power voltage
–0.4
5.0
V
VCOIN Input voltage of standby power for the RTC
1.5
3.25
V
V
I
Data pin voltage
–0.3
V
I
+0.3
V
V
I
is 2.6 V or 1.8 V. To get the details about the voltage of V
I