Appendix C Environment Requirement
C-1
Appendix C Environment Requirement
BTS3601C environment requirements involve storage, transportation, and operation
environments. These requirements are specified based on the following standards:
l
ETS 300019 Equipment Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment
l
IEC 60721 Classification of environmental conditions
C.1 Storage Environment
I. Climate environment
Table C-1
Requirements on climate environment
Item
Range
Altitude
Ÿ
5000m
Air pressure
70kPa
~
106kPa
Temperature
-40
~
+70 Celsius degree
Temperature change rate
Ÿ
1 Celsius degree/min
Relative humidity
10%
~
100%
Solar radiation
Ÿ
1120W/s²
Thermal radiation
Ÿ
600W/s²
Wind speed
Ÿ
30m/s
Rain
Drippings
II. Biotic environment
l
No microorganism like fungal or mould multiplied around or inside.
l
Free from the attack of rodential animals (such as rats).
III. Air cleanness
l
No explosive, electrically/magnetically conductive, or corrosive particles around.
l
The density of physical active substances shall meet the requirements listed in
Table C-2.
Table C-2
Requirements on the density of physical active substances
Physical active substance
Unit
Content
Suspending dust
mg/m³
Ÿ
5.00
Falling dust
mg/m²·h
Ÿ
20.0
Sands
mg/m³
Ÿ
300
Note:
Suspending dust: diameter
Ÿ
75
l
m
Falling dust: 75
l
m
Ÿ
diameter
Ÿ
150
l
m
Sands: 150
l
m
Ÿ
diameter
Ÿ
1,000
l
m