User Manual
iSiteC BTS3601C CDMA Base Station
System Description
Chapter 3 System Function
3-26
configuration and started, it will be reset; if BTS3601C is in test mode or finished
configuration, it will not be reset.
l
Abis signaling link disconnection
BTS sends a handshaking packet to BSC once a second. If no response is received
from BSC within 20 seconds, the system regards that Abis signaling link has been
disconnected. In this case, BTS3601C will shut down all the transceiver. If Abis
signaling link has disconnected continuous over 5 minutes, BTS3601C will reset itself.
IX. Power management
This function can be used to shut down the power of the whole BTS, either
permanently or temporary (The delay period can be set. For example, if it is set to 2
minutes, BTS will be powered on again 2 minutes later).
X. Environment alarm threshold management
This function includes the environment alarm threshold setting and query of MBPB
and of MTRB.
XI. MASU management
This function can be used to support MBPB-MASU communication and query MASU
board status.
3.5.4 Status Management
This function supports the active report of status, periodic report of status, board
status query, board special status query and interface status query.
When BTS3601C detects the change in physical resource status, it will send to OMC
the corresponding report. Such cases include: MTRB status change report received,
MBPB-MTRB communication link disconnected, MBPB alarm (of the major level or
above) generated or cleared as detected by MBPB itself or reported by MTRB.
I. Board status
l
MBPB statuses include:
Status type
Value range
Normal
Abnormal
Alarms generated on board
Operation status
Board not mounted
Ok (normal)
Not Mounted
CSM chip status
Error