User Manual
iSiteC BTS3601C CDMA Base Station
BTS Maintenance
Chapter 5 Part Replacement
5-5
&
Note:
The MBPM module of BTS3601C has two external optical interfaces. One is used for connection with
MTRM. The other optical interface is a 4-core connector. One pair of cores is used to access the
transmission system and to connect BSC (when STM-1 interface is used for the transmission system). The
other pair of cores is used for connection with another BTS3601C (When optical fiber chain networking
mode is adopted for BTS3601C).
MTRM has two external optical interfaces: One used for connection with MBPM and the other for
cascading with ODU3601C.
II. Plug & unplug fiber connector
This operation should be conducted very carefully. Make sure to avoid breaking the
cores inside the fiber connector.
Before plugging, align the fiber connector (of MTRM) with the fiber interface and align
its spacing arm with the fixing slot of the interface. Then carefully plug the connector
into the fiber interface until you feel the connector well engage the interface. This
indicates that the connector has been plugged in position. Then turn the spacing arm
into the corresponding fixing slot and tighten the nut. Now the fiber connector is
installed.
Prior to fiber replacement, make clear marks for fiber correspondence so that the new
fibers can be plugged right.
III. Excessive optical fibers
Put the excessive optical fibers into bellow and store same in the specified place.