Data
l
IP address of the management module management network port
l
User name and password for logging in to the management module
For details about the default data for the management module, see Default Data.
Software
PuTTY.exe
(third-party software)
Procedure
Connect the client to the management network port.
1
Connect the client to the management network port on the management module using a
network cable, as shown in
Figure 5-4
Connecting the client to the management network port
Set the client address.
2
Set the IP address, subnet mask, or route of the client to enable the client to interconnect
with the management network port.
On the client, choose
Start > Run
, enter
cmd
, and click
OK
. Then, run the
Ping
IP
address of the aggregated management network port
command to check whether the
management network port is reachable.
Log in to the management module CLI.
3
On the client, double-click
PuTTY.exe
.
The
PuTTY Configuration
window is displayed, as shown in
FusionServer G5500 Server
User Guide
5 Configuring the G5500
Issue 02 (2017-12-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
74