Parameter
Parameter
Description
Frame
Subrack number of the EDFA
Slot
Slot number of the EDFA
version same
0: consistent; 1: inconsistent
Impact on the System
When software versions are inconsistent, an unknown fault may occur.
Possible Cause
A software upgrade is abnormal.
Handling Procedure
Upgrade the software to the latest version.
Alarm Clearing Condition
The version of the internal HFA of the service module is consistent with that of the control
board.
2.3.6.5 ALM-4105 Device Log Full Event
Description
When the number of logs reaches the precaution threshold, this event is generated.
Attribute
Alarm ID
Alarm Severity
Alarm Type
4105
Warning
Event
Parameter
Parameter
Description
Frame
Subrack number of the EDFA
Slot
Slot number of the EDFA
Log Type
1: security log; 2: operation log
EDFA0820-D
Routine Maintenance Guide
2 Common Alarm Handling
Issue 02 (2018-07-02)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
24