Attribute
Alarm ID
Alarm Severity
Alarm Type
4102
Critical
Event
Parameter
Parameter
Description
Frame
Subrack number of the EDFA
Slot
Slot number of the EDFA
Impact on the System
No impact.
Possible Cause
The control module restarts automatically or is restarted.
Handling Procedure
Check whether the services are normal. If the services are normal, ignore the event.
Alarm Clearing Condition
It is an event and does not need to be cleared.
2.3.6.4 ALM-4103 Version not compare Alarm
Description
When the version of the internal HFA of the service module is inconsistent with that of the
control board, this alarm is generated.
Attribute
Alarm ID
Alarm Severity
Alarm Type
4103
Minor
Fault alarm
EDFA0820-D
Routine Maintenance Guide
2 Common Alarm Handling
Issue 02 (2018-07-02)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
23