4.2.2 Setting Physical Attributes of Console User Interface
You can configure the rate, flow control mode, parity mode, stop bit, and data bit for the console
port.
Context
Physical attributes of a console port have default values on the router and no additional
configuration is needed.
NOTE
When a user logs in to a router through a console port, the physical attributes set for the console port on
the HyperTerminal should be consistent with the attributes of the console user interface on the router.
Otherwise, the user cannot log in to the router.
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
user-interface
console
interface-number
The console user interface view is displayed.
Step 3
Run:
speed
speed-value
The baud rate is set.
By default, the baud rate is 9600 bit/s.
Step 4
Run:
flow-control
{
hardware
|
none
|
software
}
The flow control mode is set. By default, the flow-control mode is
none
.
Step 5
Run:
parity
{
even
|
none
|
odd
}
The parity mode is set.
By default, the value is none.
Step 6
Run:
stopbits
{
1.5
|
1
|
2
}
The stop bit is set.
By default, the value is 1 bit.
Step 7
Run:
databits
{
5
|
6
|
7
|
8
}
The data bit is set.
Huawei AR2200 Series Enterprise Routers