Product Warranties

One Year Warranty on Entire Conditioner

HTS Engineering, herein referred to as the "Company," warrants to the original owner that

each water-to-air heat j pump is free from defects in material and workmanship. Any part or
portion thereof (except air filters if of the throwaway type) which becomes defective under normal
use during the 1 period of this warranty will be repaired or replaced provided the Company's
examination shall prove to its satisfaction that the part was or became defective under normal
use. This warranty contemplates that first year maintenance was  arranged for with the Installer or
otherwise at the time the conditioner was purchased or installed. The Company's obligations
under this warranty are limited to: (a) repairing the defective part or (b) furnishing a replacement
part provided the defective part is returned to the factory, transportation charges prepaid. No
reimbursement will be made for expenses incurred in making field adjustments or replacements
unless specifically authorized in writing by the Company.

One Year Refrigerant Circuit Warranty

Hermetically sealed motor-compressor assemblies and all components of refrigeration

circuits not readily separable therefrom are warranted to the original owner for one (1) year .
Refrigerating circuits consist of the motor-compressor assembly, evaporator coil, condenser coil,
and interconnecting tubing. Repairs under this warranty will be made at the Company's expense
provided that the refrigerating circuit is delivered, without shipping damage, transportation
prepaid, to the factory or to a factory designated repair station, at the Company's option. This
one-year warranty does not include any other parts of the equipment such as filters, fans, fan
motors, controls, cabinet parts, electrical relays, capacitors, protective devices, or wiring. The
Company is not obligated under this warranty for field labor such as service for inspection,
removing, packing and/or reinstalling the refrigeration circuit, nor for return transportation charges.

General Conditions

The above warranties are void if the Company's equipment has been damaged, misused,

subjected to abnormal use or service or if its serial number has been altered. The Company is not

responsible for service to correct conditions due to misapplication, improper installation,

inadequate wiring, incorrect voltage conditions or unauthorized opening of the refrigeration circuit,

operation at abnormal temperatures and water flow rates, operation on an open condenser water

circuit, nor for consequential damages. In case the Company's equipment is installed in

conjunction with cabinets, grilles, louvers, controls or other parts manufactured by others, these

warranties shall apply only to the Company manufactured portion of the equipment. The

conditions of this warranty plan are effective for eighteen (18) months from date of factory

shipment. The Company reserves the right to make a handling and inspection charge in the case

of parts or equipment improperly returned as defective and/or as being in warranty.

Содержание HRP 30 C 2

Страница 1: ...SEPT 2001 INSTALLATION AND MAINTENANCE Visit us on the web at w w w www htseng com...

Страница 2: ...he carrier within 48 hours to establish your claim and request their inspection and report Our Warranty Claims Department should then be contacted All cartons are marked with UP arrows and should be t...

Страница 3: ...tor will find it beneficial to confer with piping sheet metal ceiling and electrical foremen together before installing any conditioners Chassis It is recommended that a piece of rubber or neoprene pa...

Страница 4: ...phosphate is recommended as a cleaning agent during flushing However many localities prohibit the introduction of phosphates into their sewage systems The current recommendation is to contact your lo...

Страница 5: ...ermostat is the automatic changeover type set system switch to the AUTO position and depress the heat setting to the warmest selection Some conditioners have built in time delays which prevent the com...

Страница 6: ...wing Number 101 Engineer Project Revision Sept 2001 NOTES Temporary riser supports provided contractor to supply riser clamps to support risers in multistory applications Return Air Opening is on the...

Страница 7: ...nit shown Unit Includes hose kits and shut off valves Risers are made with type M copper expanded connections are provided Contractor to provided couples where piping not swagged Optional 2 x 8 Outsid...

Страница 8: ...Engineer Project Revision Sept 2001 NOTES Any combination of discharge arrangements are available Supply Riser is towards the center line of unit All Handings determined looking at return air opening...

Страница 9: ...RETURN AIR PANEL MODEL SIZE A B C D HRP 30 40 36 18 14 32 HRP 60 80 38 20 16 34 Contractor Date Drawing Number 105 Engineer Project Revision Sept 2001 Notes...

Страница 10: ...USTIC RETURN AIR PANEL MODEL SIZE A B C D HRP 30 20 30 5 18 36 HRP 40 20 30 5 18 36 HRP 60 22 32 5 20 36 HRP 80 22 32 5 20 38 Contractor Date Drawing Number 107 Engineer Project Revision Sept 2001 Not...

Страница 11: ...clearance between heat pump return air flange and return air panel Mount Return Air Panel centered in front of Return Air opening For REAR risers allow an additional 5 clearance at back of units Inst...

Страница 12: ...y others Drywall frame is to be mounted such that there is 1 2 maximum clearance between heat pump return air flange and return air panel Mount Return Air Panel centered in front of Return Air opening...

Страница 13: ...Discharge Grille or Ductwork Installing contractor to insulate drywall enclosure with acoustical thermal batt insulation Recommended Opening Width Opening Width Opening Width Opening Width Back Discha...

Страница 14: ...provided contractor to supply clamps for multistory applications Supply riser towards center line of unit Riser couplings are not provided expanded connections are provided RISER SLEEVING SIZES AND L...

Страница 15: ...ck capacitor 2 Wires may be loose or broken Replace or tighten 3 The high pressure may have tripped due to a fouled or plugged condenser b lack of or no condenser water c too warm condenser water d no...

Страница 16: ...k all relays relaying and contacts 3 Check run capacitor 4 Check high pressure switch 5 Check low temperature switch 6 See if reversing valve has not fully shifted to either side Insufficient cooling...

Страница 17: ...ing Adjust for clearance 2 Check for bent fan wheel Replace if damaged Check for loose fan wheel on shaft Tighten 3 Make sure compressor is floating free on its isolator mounts 4 Check for tubing touc...

Страница 18: ...be seen through the filter when held up to sunlight or a bright light it should be changed A more critical standard may be desirable 3 The condensate drain pan should be checked annually and cleaned...

Страница 19: ...bient Air 50 o F 10o C 50 o F 10o C Normal Ambient Air 80 o F 27o C 70 o F 21o C Max Ambient air 110 o F 38o C 85 o F 29o C Min Entering Air 50 o F 10o C 50 o F 10o C Normal Entering Air db wb 80 67 o...

Страница 20: ...HRP 60 208 230 1 8 5 8 1 47 0 68 15 HRP 80 208 230 1 11 7 11 0 56 2 7 20 NOTES 1 Minimum circuit ampacity are for non electric heat units 2 Maximum fuse size should be HACR type circuit breaker C B w...

Страница 21: ...HRP Wiring Diagram...

Страница 22: ...ill be made at the Company s expense provided that the refrigerating circuit is delivered without shipping damage transportation prepaid to the factory or to a factory designated repair station at the...

Страница 23: ...For Parts and Service Call HTS Engineering Ltd 115 Norfinch Drive North York Ontario Tel 416 661 3400 1 800 850 0567 Fax 416 661 0100 SEPT 2001 I M 1 0...

Отзывы: