background image

LP-436 Rev. 5.20.15

11

•  The length of the horizontal vent pipe must not exceed 

75% of the vertical vent pipe height and never exceed 
20’ (6.1 m).

•  All horizontal runs must have a minimum rise of ¼” (21 

mm/m) per foot of run. See Figure 10.

•  All joints must be securely fastened with sheet metal 

screws or other approved means.

•  All single wall vent piping must maintain a minimum of 

6” (15.2 cm) of clearance from combustible materials.

•  Venting systems made with single wall piping cannot 

pass  through  any  attic,  inside  wall,  crawl  space, 
confined space, or any floor.

•  The  vent  piping  must  be  accessible  for  inspection, 

cleaning, and replacement.

Figure 10 - Power Vent Kit Installation

3. Optional Side Wall Power Vent Kits

This  water  heater  is  approved  for  installation  with  a 
TjernlundTM side wall power vent kit. See Figure 10. This kit 
can be installed as part of a new installation or retrofitted onto 
an existing installation. The kit consists of a power venter and 
vent  termination  assembly. See Table  5  and  Figure  12. Vent 
piping  is  not  included.  Before  beginning  the  installation  of 
the power vent kit, make sure that it is the appropriate kit for 
your model water heater. See Tables 5 and 6. Make sure that 
the water heater is located so all vent terminal clearances will 
be respected. See Figure 11. Maximum equivalent vent pipe 
length is 50’ for each model. For complete instructions on the 
side wall vent kit installation, consult the manual that comes 
with the kit.

When  using  an  optional  power  vent  kit,  the  power  venter 
must be properly secured against the outside wall. Failure to 
properly  secure  the  power  venter  can  result  in  exhaust  gas 
leak, property damage, personal injury, or death.

Содержание CG N65 Series

Страница 1: ...l injury or death HTPreservestherighttomakeproductchangesorupdateswithoutnoticeandwillnotbeheldliablefortypographical errors in literature NOTETO CONSUMER PLEASE KEEP ALL INSTRUCTIONS FOR FUTURE REFER...

Страница 2: ...CINITY OFTHIS OR ANY OTHER APPLIANCE WHATTO DO IFYOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supp...

Страница 3: ...dividual such as a fire chief fire marshal chief of a fire prevention bureau labor department or health department building official or For the Installer This water heater must be installed by qualifi...

Страница 4: ...RSONAL INJURY OR DEATH DO NOT USE THIS WATER HEATER IF ANY PART HAS BEEN SUBMERGED IN WATER Immediately call a qualified service technician The water heater MUST BE replaced if it has been submerged A...

Страница 5: ...require a 120oF or lower temperature setting to prevent severe personal injury or death due to scalding F Water Temperature Adjustment If the water heater is going to have a set temperature above 120...

Страница 6: ...DS concentration will greatly accelerate lime and scale formation in the hot water system Most high TDS concentrations precipitate out of the water when heated This can generate a scale accumulation t...

Страница 7: ...water heater See Figure 13 for proper installation The drain pan should be at least 4 10 2 cm larger than the diameter of the water heater and at least 1 2 5 cm deep providing access to the drain val...

Страница 8: ...dern buildings additional fresh air may need to be provided For instructions on obtaining additional air supply see the requirements for confined spaces 2 Requirements for Confined Spaces In the US re...

Страница 9: ...for all the appliances installed in that confined space See Figure 7 When ducts are used they shall be of the same cross sectional area as the free area of the openings to which they connect The mini...

Страница 10: ...afthood assembly is installed Failure to follow these instructions can result in property damage personal injury or death When installing the water heater make sure the location allows clear viewing o...

Страница 11: ...stallation with a TjernlundTM side wall power vent kit See Figure 10 This kit can be installed as part of a new installation or retrofitted onto an existing installation The kit consists of a power ve...

Страница 12: ...tally L Clearance above paved sidewalk or paved driveway located on public property 7 2 13 m M Clearance under veranda porch deck or balcony 12 Table 3 Side Wall PowerVentTermination Requirements 1In...

Страница 13: ...ssure and or temperature the manufacturer has installed a temperature and pressure relief valve that meets the requirements of the Standard for Relief Valves and Automatic Gas Shut Off Devices for Hot...

Страница 14: ...ates or CAN CSA B149 1 NationalGas and Propane InstallationCode in Canada Only new piping with cleanly cut threads may be used The water heater and its gas connection must be leak tested before placin...

Страница 15: ...ly manual shut off valve must be closed NOTE Theinputratingoftheapplianceisbasedoninstallation and operation at sea level up to elevations of 2 000 ft Low NOx models are certified to operate to 2 000...

Страница 16: ...o disconnecting Verify all wiring connections before relighting the water heater Wiring errors can result in property damage personal injury or death Damages to this product due to improper wiring ARE...

Страница 17: ...LP 436 Rev 5 20 15 17 Figure 17 Wiring the Control...

Страница 18: ...nections been properly installed and are they leak free Is the water heater full of water Gas Connections Complete Is the gas supplied to the water heater the same type indicated on the water heater r...

Страница 19: ...ures at the hot water outlet Always remember to check the hot water coming out of any faucet with your hand before use This will reduce the risk of scalding related injury Figure 18 Thermostat D Out o...

Страница 20: ...erly refer to Drafthood Operation G Anode This water heater is equipped with multiple anode rods that are designed to prolong the life of the glass lined tank By the electrolytic action these anodes a...

Страница 21: ...ater follow these two easy steps 1 Consult the Troubleshooting Guide in this manual It will guide you to the most common problems experienced with a gas fired water heater The solutions you find liste...

Страница 22: ...019 16 Access Door 8800P 018 17 Outlet Nipple 8800P 032 18 Nipple Temperature and Pressure ReliefValve 8800P 033 8800P 034 19 Temperature and Pressure ReliefValve 8800P 035 8800P 036 20 Anode 8800P 03...

Страница 23: ...water heater The diagnostic system is designed to give the user or qualified service technician a visual indication of the operational status of the different parts of the water heater s control syste...

Страница 24: ...LP 436 Rev 5 20 15 24...

Страница 25: ...LP 436 Rev 5 20 15 25...

Страница 26: ...LP 436 Rev 5 20 15 26...

Страница 27: ...LP 436 Rev 5 20 15 27...

Страница 28: ...LP 436 Rev 5 20 15 28...

Страница 29: ...OXIDE DETECTORS At the time of installation of the side wall horizontal vented gas fueled equipment the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an...

Страница 30: ...TING SYSTEM PROVIDED When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment the instruct...

Страница 31: ...at optimum efficiency 2 Maintain all related heating components in good operating condition 3 Use the water heater in an open system with a properly sized and installed thermal expansion tank 4 Use th...

Страница 32: ...is denied If all warranty conditions are satisfied HTP will provide replacement parts to the retailer For questions about the coverage of this warranty please contact HTP at the address or phone numbe...

Страница 33: ...LP 436 Rev 5 20 15 33 Maintenance Notes...

Страница 34: ...f Installation Installation Address Product Name Serial Number s Comments Installer s Code Name Installers Phone Number Signed by Installer Signed by Customer Installation Notes IMPORTANT Customer Ple...