LP-436 Rev. 5.20.15
12
Figure 11 - Side Wall Power Vent Installation Detail
When Using a Power Vent Kit, The Vent Termination Must Have:
US Installations
1
Canadian Installations
2
A) Clearance above grade, veranda, porch, deck, or balcony
12”
30 cm
B) Clearance to window or door that may be opened
3’
1.2 m below or to the side of
opening; 30 cm above opening
C) Clearance to permanently closed window
*
*
D) Vertical clearance to ventilated soffit located above the terminal within a
horizontal distance of 2’ from the center line of the terminal
*
*
E) Clearance to unventilated soffit
*
*
F) Clearance to outside corner
*
*
G) Clearance to inside corner
*
*
H) Clearance to each side of center line extended above meter / regulator
assembly
3’
*
I) Clearance to service regulator vent outlet
3’
*
J) Clearance to non-mechanical air supply inlet to building or the combustion
air inlet to any other appliance
3’
1.2 m below or to the side of
opening; 30 cm above opening
K) Clearance to a mechanical air supply inlet
6’
91 cm above if within 3 m
horizontally
L) Clearance above paved sidewalk or paved driveway located on public
property
7’
†
2.13 m
M) Clearance under veranda, porch, deck, or balcony
12”
‡
*
Table 3 - Side Wall Power Vent Termination Requirements
1
In accordance with current ANSI Z223.1 / NFPA 54 National Fuel Gas Code.
2
In accordance with current CAN/CSA B149.1 National Gas and Propane Installation Code.
*
Clearance in accordance with local installation codes and the requirements of the gas supplier.
†
Vent shall not terminate directly above a sidewalk or paved driveway located between two single family dwellings that serves both dwellings.
‡
Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
Model
Kit
#
Motor
Dimensions (Inches)
Vent Hood
Rough-In
Inlet /
Outlet
Watts Amps
A
B
C
D
E
F
G
H
I
J
CG125N73
1
95
1.26
7 7/8
7
11
4
7 1/2
(sq)
7 1/8
13
(sq)
8 5/8
7 3/8
11
8
(sq)
4
CG150N73
to
CG300N65
2
224
1.51
9 1/4 8 1/2 11 1/2
6
8 1/2
(dia)
12
(sq)
9 1/2
9 1/2
10
9
(dia)
6
Table 4 -
Power Venter Including Terminal - NOTES: Max vent length based on total of straight vent pipe plus 11’ for 6” dia. 90
o
elbow, 7’
for a 4” 90
o
elbow, 5’ for a 6” 45
o
elbow, 4’ for a 4” dia. 45
o
elbow, 4’ for a 8” to 6” reducer, and 5’ for a 6” to 4” reducer.
Содержание CG N65 Series
Страница 17: ...LP 436 Rev 5 20 15 17 Figure 17 Wiring the Control...
Страница 24: ...LP 436 Rev 5 20 15 24...
Страница 25: ...LP 436 Rev 5 20 15 25...
Страница 26: ...LP 436 Rev 5 20 15 26...
Страница 27: ...LP 436 Rev 5 20 15 27...
Страница 28: ...LP 436 Rev 5 20 15 28...
Страница 33: ...LP 436 Rev 5 20 15 33 Maintenance Notes...