Specifications
HTO-100
HTO-150
HTO-200
HTO-250
HTO-300
Salt Used - Per Regeneration
6.0 lbs
9.0 lbs
12.0 lbs
15.0 lbs
18.0 lbs
Water Used - Regeneration
86.4 gal
148 gal
162.4 gal
216.0 gal
224.8 gal
Hardness Removal - Grains
25,000
37,500
50,000
67,500
75,000
Tank #1 Carbon Quantity (ft3)
1.0 ft
1.50 ft
2.0 ft
2.5 ft
3.0 ft
Tank #2 Resin Quantity (ft3)
1.0 ft
1.50 ft
2.0 ft
2.5 ft
3.0 ft
Tank Size
9x48
10x54
12x52
13x54
14x65
Tank Jacket / Media Loaded
Yes
Yes
No
No
No
Brine Tank (Inches)
BTR 18.1 x 34.5
BTS 15.0²x34.7
BTR 18.1 x 34.5
BTS 15.0²x34.7
20.3 x 37.4
20.3 x 37.4 23.0 x 40.5
Salt Storage Capacity
BTS 240 lbs BTR
270 lbs
BTS 240 lbs BTR
270 lbs
350 lbs
350 lbs
420 lbs
Flow Rate @ 15 psi Pressure Drop
7.2 gpm
7.4 gpm
9.0 gpm
9.2 gpm
9.2 gpm
Flow Rate @ 25 psi Pressure Drop
10.0 gpm
10.1 gpm
11.9 gpm
12.1 gpm
12.1 gpm
Back Wash Flow Rate
4.0 gpm
5.0 gpm
7.0 gpm
8.0 gpm
10.0 gpm
Shipping Weight
154 lbs
171 lbs
214 lbs
225 lbs
232 lbs
Regeneration Type
Up Flow
Plumbing Connections
89 Model 1” Straight NPT. 785 Model 3/4” 90
0
Elbows & 1” Straight NPT
Resin Type
Aquafine 8% cation exchange resin
Carbon Type
Catalytic Carbon
Electrical Requirements
Input 120V 60 Hz - Output 12V 650mA
Water Temperature
40°F and 110°F (4°C - 43°C)
Water Pressure
Min. 30 - Max. 125 psi
SPECIFICATION
Working Temperature:
This unit must be
operated at temperatures between 40°F and
110°F (4°C - 43°C).
Working Pressure:
This water softener
must be operated on pressures
between 30 psi to 125 psi. If the water
pressure is higher than 125 PSI, use a
pressure reducing valve in the water supply
line to the softener.
Voltage = 120V / 60 Hz
Pipe Size = 3/4” and 1”
• At the stated service flow rates, the
pressure drop through these devices will
not exceed 15 psig.
• The manufacturer reserves the right
to make product improvements which
may deviate from the specifications
and descriptions stated herein, without
obligation to change previously
manufactured products or to note the
change.
* Do not use water that is microbiologically
unsafe without adequate disinfection
before or after the system.
Peak flow rates intended for intermittent
use only (10 minutes or less) and are for
residential applications only. Do not use
peak flow rate for commercial applications
or for a continuous rate when treated
water supplies are geothermal heat pump,
swimming pool, etc.
For satisfactory operation, the pumping rate
of the well system must equal or exceed
indicated backwash flow rate.
All units come with plastic bypass
Maximum Iron
= 1.5 ppm
Maximum Hydrogen Sulfide
= 0.0 ppm
Maximum Manganese
= .75 ppm
pH
= 6.5 to 8.5
Models
A (Inches) B (Inches)
HTO-100
58
9
HTO-150
64
10
HTO-200
62
12
HTO-250
64
13
HTO-300
75
14
SYSTEM DIMENSIONS
All units are factory programmed to the below specifications. Alteration should only be done by a factory trained technician or after consultation with one of our technical
representatives if you have any questions please call
877-288-9888
.