22
2.
1.
4X Screws
4.
2 X Motor Screws
3.
Wire connection to Circuit Board
Circuit
Board
Special Tool
Impeller
Remove
6X
screws
Meter
Support
Meter Cable
1.
2.
3.
4.
5.
2X Clips
METER ASSEMBLY REPLACEMENT
(For Models Manufactured BEFORE
Valve Serial # Date of November 2015)
1.
Disconnect the meter cable from the meter.
2.
Disconnect the valve from bypass by removing clips
3.
Remove the coupling adapter from the valve
4.
Remove six screws and pull out the meter support and impeller.
5.
Replace meter with the help of special tool and re-assemble the removed
components back in the section
REPLACE MOTOR
1.
Remove Screws from the back of the valve and pull the cover
2.
Remove all connections from the circuit board
3.
Remove the two screws from the motor. Remove
the motor and watch for the pin under the motor.
4.
Replace the motor, connections and cover
WARNING!
ELECTRICAL SHOCK
HAZARD!
UNPLUG THE UNIT
BEFORE REMOVING THE
COVER OR ACCESSING ANY
INTERNAL CONTROL PARTS