14
15
MENU
SET
System initializing
Please wait
MENU
SET
MENU
SET
MENU
SET
MENU
SET
This function accepts the values if changed and advance to the
next page in the menu
These buttons increase or decrease the value of the settings
while in the programming mode.
This function enters the basic set up information
required at the time of installation.
Key Pad Configuration:
1. Connect the Transformer to the Valve
Plug the 12-volt transformer into a 120 VAC 60 Hz outlet.
3. Screen Display
When power is supplied to
the control, the screen will
display “INITIALIZING WAIT
PLEASE” while it finds the
service position.
2. Add Water to Brine Tank
Open the brine tank /cabinet salt lid and add water as
per the chart below. Do not add salt to the brine tank
at this time.
Sample
Connection
Sample
Connection
SERVICE
BYPASS
Sample
Connection
Sample
Connection
SERVICE
BYPASS
MENU
SET
Flow Rate 3 gpm/min
18-Apr-2017 10:35AM
Remain 010000GAL
Capacity 01000 GAL
The controller will show the following on the
screen: Time, Date and Gallons Remaining for
Regeneration
Date and Time
Hardness
Manual Regen.
Dealer Information
Main Menu
Regen. Now?
Regen. Tonight?
Press
To Cancel
Press
To Confirm
Brine Drawing
Any Key 3s To Next
13:59
18%
18%
Backwashing
Any Key 3S to Next
Rinsing
Any Key 3S to Next
Skip this cycle by
pressing any key for 3
seconds
IMPORTANT!
Complete
the Backwashing cycle
to let the air out of the
system
Complete this cycle to
settle the media
Brine Refill
Any Key 3S to Next
IMPORTANT!
C
omplete this cycle to
let the air out of the
injector system
18%
18%
Familiarize with Button Configuration:
4. Manually Regenerate the Valve
If screen is locked, press Menu Key
for 5 seconds to unlock
Manually Regenerate the Valve and move it to backwash
position. Press
“MENU”
Key and Scroll down
using Up and Down Arrow buttons to “Manual Regen”.
Press
“SET”
Select “Regen Now”
BTR-100 -2.5 US Gallons
BTR-145 - 3.25 US Gallons
BTR-200 - 5.5 US Gallons
STARTUP INSTRUCTIONS
CAUTION!
FAILURE TO FOLLOW STEP 2
WOULD DEPLETE THE RE-
SERVE CAPACITY OF RESIN
AND RESULT IN HARDNESS
LEAKAGE. IN CASE STEP 2
IS MISSED, THEN SOFTENER
SHOULD BE REGENERATED
TWICE OR THRICE BACK TO
BACK TO RESTORE THE RE-
SERVE CAPACITY OF RESIN