20
21
NOTE
Full disassembly requires specialty wrenches
item’s 60010116 and 60010117 and should only
be attempted by a qualified service technician.
If there is no indication of leaking or fouling of
the inlets due to harsh water conditions then
there should be no need to disassemble.
K
L
H
I
J
Apply grease to
Parallel Tank
Connector O ring
Apply grease to
Tank Adaptor O
ring
Apply grease to the 1” Straight
Connector O rings
Apply grease to
Tank Connector
O ring
Apply grease to O-ring
Seal to Distributor Tube
A.
Parallel tank connector w/ O ring
B.
Top pipe connector
C.
Bottom pipe connector
D.
Tank adaptor w/ O ring
E.
Red Clips (4pcs)
F.
1 “ x 3 Straight , w O ring
H.
Clamp ring
I.
Valve base
J.
Tank Base
K.
O ring
L.
Retainer ring
Disassemble the adaptor
D
B
A
C
E
E
F
SERVICING OF PARALLEL ADAPTOR
Tank and Valve Connection Parts
Ensure all Oring on both tank
connectors are properly dissembled
and apply a good amount of grease.
Meter Cable
2X Clips
3.
2.
4.
5.
1.
METER ASSEMBLY REPLACEMENT
(For Models Manufactured AFTER
Valve Serial # Date of November 2015)
1.
Disconnect the meter cable from the meter.
2.
Disconnect the valve from bypass by removing clips
3.
Remove the coupling adapter from the valve
4.
Remove the meter support and then the impeller out from the coupling and
clean it
5.
Replace meter with the help of special tool and re-assemble the
removed components back in the section