20
Maintenance Kit
(60010307)
1.
Follow steps 1 to 6 of timer /Powerhead
replacement.
2.
Remove four screws from the plate on the
valve body.
3.
Remove the plate from the valve body and pull the
Piston Assembly from the valve. The brine valve
assembly can also be removed in this stage.
4.
Remove the seal spacer assembly, grease it
with silicone lubricant (# 92360) and put back in.
5.
Replace piston assembly followed by timer assembly.
6.
Replace the piston assembly and reverse
following steps in this section
Remove 4 X
Screws
Plate
Seal and
Spacer
Brine Valve
Assembly
Piston
Assembly
Fig. 2
Fig. 3
INSPECTION AND REPLACEMENT OF PISTON ASSEMBLY AND
SEAL AND SPACER KIT
Screen
1.
3.
5.
2.
4.
2X Screws
Gasket
Injector Cap
Injector Assembly
CLEAN INJECTOR ASSEMBLY
1.
Remove the two screws from the injector cap
2.
Pull the injector cap and gasket
3.
Pull the injector assembly and Screen
4.
Replace/Clean screen and injector assembly and
put it back in the valve in appropriate location as
shown
5.
Put back the injector cap. Grease the injector
assembly orings and injector cap gasket. Care
should be taken to put all orings and gaskets in
place and grease them (# 92360) so that they dont
pinch
6.
After cleaning the injectors it is important to cycle the
valve completely with water and allow to refill for 1 - 2
minutes to purge all air from the brine system. Air in
the brine system can cause the unit not to draw brine.
WARNING!
ELECTRICAL SHOCK
HAZARD!
UNPLUG THE UNIT
BEFORE REMOVING THE
COVER OR ACCESSING ANY
INTERNAL CONTROL PARTS