- 31 -
6. Maintenance, service and disposal ________________________________
By performing regular maintenance on the PowerRiv
®
blind rivet setting tool, you can
ensure touble free operation and prolong its the service life.
General information:
1.
Maintenance work may be performed only by qualified service personnel.
2.
Original HS-Technik replacement parts must be used.
3.
Document all maintenance work with
- serial number of the tool
- date
- rivet count
- type of work performed
The following maintenance and checks must be performed at regular intervals and when
the tool is heavily soiled.
Check the nosepiece (1) daily for wear and replace if necessary.
Clean the chuck jaws (6) and the chuck jaw housing (5)
Check the compression spring (8) for shortening replace if necessary.
Clean the contacts on the battery and the power tool with alcohol.
The tube guiding the mandrel into the collection container should be cleaned daily (by
blowing it out carefully from the back with compressed air) to remove debris and shavings.
The riveting tool must not be cleaned with fat-solvent agents or water.
Im Martelacker 12 – D-79588 Efringen-Kirchen – Phone 0 76 28 - 91 11- 0 – Fax 0 76 28 - 91 11-90