- 17 -
WARNING
Make sure the po/- is correct.
When replacing batteries, make sure the new battery is not inserted until the LEDs have
gone out (red or green).
If a battery is replaced very quickly, the electronics may retain the status of the previous
battery pack.
3.2.1 Charging process
Via an initialization routine, the voltage, temperature, short circuits and reverse polarity
of the inserted battery are checked.
Prior to starting the charging process, the temperature contacts (NTC contact, etc.) are
checked. If the temperature contacts are OK, the battery will be charged.
If the battery is too hot, it can stay in the charging station, and when it has cooled down,
it will automatically start the charging again.
If the red LED lights up, the charging process will start using the special HST frequency
modulation impulse process® and charge the battery based on how depleted the battery is.
During the charging process, the voltage and temperature of the cells and the remaining
charging time are continuously monitored.
Taking all of the parameters into account, the charging current and remaining charging
time varies on a case-by-case basis. The installed fans switch on automatically, as needed
during each charging process.
Every charging process can be recorded on an optional memory chip for subsequent
evaluation.
Содержание HST-MV3-02
Страница 31: ...Notes ...