Insert a reusable plastic interposer installation cap into each interposer.
Caps should be clean, free of oil, dust or debris.
If cap is dirty or worn, replace with new cap.
Use top press plate to push directly down on interposers and lock them into place.
Press force should not exceed 500N for 300 pos, 400N for 200 pos, and 300N for
100 pos.
If a mechanical press is used, force must be measureable and controlled.
Example:
One 200-signal connector: do not exceed 400N insertion force
Two 200-signal connectors (400 signals): do not exceed 800N insertion force.