Procedure
1.
Enter the
switchshow
command to verify the switch mode.
AG Mode
is displayed if the switch is in AG mode.
Native
is displayed if the switch is in Native mode.
2.
Enter the
switchdisable
command to disable the switch.
The switch must be disabled in order to enable or disable AG mode.
3.
Enter the
ag --modeDisable
command to disable AG mode.
4.
Enter the
ag --modeshow
command to verify that AG mode is disabled.
Powering the switch on and off
HPE StoreFabric SN3600B 32Gb FC Switch
• Power is supplied to the switch as soon as the power cord is plugged into the switch and power
source.
• To power the switch off, remove the power cord. All devices are returned to their initial state the next
time the switch is powered on.
HPE StoreFabric SN6600B 32Gb FC Switch
• Power switches are located on the nonport side of the switch.
• If the HPE StoreFabric SN6600B 32Gb FC Switch is mounted in a rack, you must remove the plenum
to access the power switches.
• Power is supplied to the switch as soon as the first power supply is connected and powered on.
• To power the switch off, power off the power supplies present by setting the AC power switch to
O
. All
devices are returned to their initial state the next time the switch is powered on.
LEDs
The switch LEDs indicate system activity and status. There are three LED states: no light, a steady light,
and a flashing light. Flashing lights can be slow, fast, or flickering. The lights are green or amber.
The LEDs can flash green or amber during boot, POST, or other diagnostic tests. This is normal; it does
not indicate a problem unless the LEDs do not indicate a healthy state after all boot processes and
diagnostic tests are complete.
Figure 13: LEDs on the port side of the HPE StoreFabric SN3600B 32Gb FC Switch
on page 24
and
Figure 14: LEDs on the port side of the HPE StoreFabric SN6600B 32Gb FC Switch
on page
24 show the LEDs on the port side of the switch. The port status LEDs for the FC ports are arranged left
to right, and correspond to the upper and lower ports in each pair.
Powering the switch on and off
23