Figure 11: Inserting a 16 Gb/s SFP+ transceiver in an FC port
NOTE:
SN6600B 32Gb FC Switch only-Each QSFP+ transceiver also has a pull tab. Use the pull tab on
these transceivers to help push the transceiver into the port.
Transceivers are keyed so that they can only be inserted with the correct orientation. If a
transceiver does not slide in easily, ensure that it is correctly oriented. Push the correctly oriented
transceiver into the port until it is firmly seated and the latching mechanism clicks.
1. Pull tab
2. QSFP cable
3. QSFP transceiver
Figure 12: Inserting a QSFP transceiver in an FC port (SN6600B 32Gb FC Switch only)
2.
Connect the FC cables from the switch to your host and storage devices.
a.
Remove the plastic protector caps from the FC cable ends (if there are any) and position the cable
connector so that it is oriented correctly.
b.
Position a cable so that the key (the ridge on one side of the cable connector) is aligned with the
slot in the transceiver (see
Figure 12: Inserting a QSFP transceiver in an FC port (SN6600B
32Gb FC Switch only)
on page 20).
c.
Insert the cable into the transceiver until the latching mechanism clicks.
20
Login and Configuration