background image

Login and Configuration

This chapter provides configuration information for the HPE StoreFabric SN3600B 32Gb FC Switch or
HPE StoreFabric SN6600B 32Gb FC Switch.

Setting up the switch

To set up the switch, you will need the following:

• Standard screwdriver
• WWN, located on the switch ID pull-out tab
• Ethernet connection (hub or switch)
• Ethernet and FC cables
• Disk array with FC ports
• If you are using static IP addressing, you will need the following items (not required if using DHCP):

◦ Fixed IP address (IPv4 or IPv6) for the switch
◦ Subnet mask value
◦ Default gateway value

Connecting the serial cable

Procedure

1.

Connect the serial cable to the serial port on the switch and to an RS-232 serial port on the
workstation.

If the serial port is RJ-45 instead of RS-232, remove the adapter on the end of the serial cable and
insert the exposed RJ-45 connector into the RJ-45 serial port on the workstation.

2.

Disable any serial communication programs running on the workstation.

3.

Open a terminal emulator (such as HyperTerminal on a PC, or TERM, TIP, or Kermit in a UNIX
environment) and configure as follows:

For most Windows systems:

Bits per second: 9,600

Data bits: 8

Parity: None

Stop bits: 1

Flow control: None

For most UNIX systems:

Enter 

tip /dev/ttyb -9600

If 

ttyb

 is already in use, enter 

tip /dev/ttya -9600

Logging in to the serial console port

Procedure

1.

Verify that the switch has completed POST.

When POST is complete, the switch status and switch power LEDs return to a normal state.

2.

When the terminal emulator stops reporting information, press 

Enter

 to display the login prompt.

3.

Log in to the switch as 

admin

, using the default password, 

password

.

16

 Login and Configuration

Содержание StoreFabric SN3600B

Страница 1: ...ide Part Number 870876 002 Published March 2017 Edition 2 Abstract This document provides information on installing configuring and maintaining the HPE StoreFabric SN3600B 32Gb Fibre Channel Switch or HPE StoreFabric SN6600B 32Gb Fibre Channel Switch ...

Страница 2: ...icense from Hewlett Packard Enterprise required for possession use or copying Consistent with FAR 12 211 and 12 212 Commercial Computer Software Computer Software Documentation and Technical Data for Commercial Items are licensed to the U S Government under vendor s standard commercial license Links to third party websites take you outside the Hewlett Packard Enterprise website Hewlett Packard Ent...

Страница 3: ...17 Setting the date and time 17 Installing Transceivers 19 Verifying the configuration 21 Backing up the configuration 21 Installing and activating Port Upgrade licenses 21 Configuring the zones and selecting devices 22 Fabric OS Native and AG modes 22 Disabling and enabling AG mode 22 Powering the switch on and off 23 LEDs 23 Resources and other information 29 Related information 29 Hewlett Packa...

Страница 4: ...ischarge recommendations 36 Grounding methods 36 Warranty and regulatory information 37 Warranty information 37 Regulatory information 37 Belarus Kazakhstan Russia marking 37 Turkey RoHS material content declaration 38 Ukraine RoHS material content declaration 38 4 Contents ...

Страница 5: ...nts of a small to medium sized workgroup environment HPE StoreFabric SN6600B 32Gb FC Switch The HPE StoreFabric SN6600B 32Gb FC Switch is a 64 port autosensing 4 8 10 16 or 32 Gb s FC switch that delivers the latest HPE multi chip architecture for FC SANs It is an enterprise class switch designed to handle the large scale SAN requirements of an enterprise environment and can also be used to addres...

Страница 6: ...art number the switches may come with optics or without optics If ordered without optics order transceivers and cables separately The HPE StoreFabric SN3600B 32Gb FC Switch and HPE StoreFabric SN6600B 32Gb FC Switch support only transceivers and cables labeled either HPE B series or Brocade SFP QSFP SN6600B 32Gb FC Switch only or HPE B series cable Installing the SN3600B Switch in a rack using the...

Страница 7: ...ock washers Two 1 4 inch flat washers CAUTION For proper airflow the SFP media side of the device port side must face the rear of the rack This allows cool air to enter the front of the rack and exit from the rear To install the switch in a rack using the Rack Mount Kit 1 Verify that the required parts and hardware are available See SN3600B Rack Mount Kit hardware 2 Place the switch on a flat surf...

Страница 8: ...e rear mounting brackets to the rear rack uprights For an HPE 10000 Series Rack assemble each of the brackets using two 10 32 x 1 2 inch Phillips panhead screws with captive star lock washers and two 10 adapter washers as shown in HPE 10000 Series Rack Figure 2 HPE 10000 Series Rack 8 Setup and install ...

Страница 9: ...oosely as shown in HPE 10000 Series Rack Do not tighten the nuts Figure 3 HPE 10000 Series Rack Depending on the rack you are using complete one of the following tasks For an HPE 10000 Series Rack install two 10 32 x 1 2 inch Phillips panhead screws with captive star lock washers and two 10 adapter washers in the upper and lower holes on the right rail Then install two 10 32 x 1 2 inch Phillips pa...

Страница 10: ...w hole marked 8 and one screw hole marked 16 7 Secure the two inner rails one on each side to the device using the appropriate number of screws 8 Install the plenum included in the switch accessory kit 9 From the front of the rack slide the switch with inner rails attached onto the outer rails taking care to align the inner rails with the attachment screws on the outer rails at the rear of the rac...

Страница 11: ... This configuration optimizes performance by Providing better airflow by using a plenum to force cool air to enter the switch from the front of the rack Providing room for a gradual bend in the fiber optic cables because the port side of the switch is set back from the edge of the rack Use only the screws provided in the Rack Mount Kit Using other screws can cause damage to internal components NOT...

Страница 12: ...sure that airflow and temperature requirements are met on an ongoing basis Secure the rack to ensure stability in case of unexpected movement Rack mount installation To install the switch in a rack using the Rack Mount Kit 1 Place the switch on a flat surface and attach each inner rail to the switch using three flat head screws Figure 6 Attaching the inner rails to the switch 2 Choose a rack mount...

Страница 13: ... outer rail to the rear mounting bracket using a Phillips screw NOTE Tighten the rear screws just enough for the end of the screw to go through the rear brackets Later in the procedure you will need room to slide the inner rail between the screw head and the outer bracket 5 From the front of the rack slide the switch with inner rails attached onto the outer rails taking care to align the inner rai...

Страница 14: ...upplies by setting the power switches to the ON I position The power supply LEDs are amber until the Power On Self Test POST is complete and then change to green The HPE StoreFabric SN6600B 32Gb FC Switch takes several minutes to boot and complete POST NOTE When installed the plenum covers the power supply switches and LEDs However the LEDs are visible through the air holes in the front of the ple...

Страница 15: ...to protect against AC failure Ensure that the cords have a minimum service loop of 6 inches available and are routed to avoid stress 5 HPE StoreFabric SN6600B 32Gb FC Switch only Power on the power supplies by setting both AC switches to the on position The power supply LEDs are amber until POST is complete and then change to green The switch takes several minutes to boot and complete POST NOTE HP...

Страница 16: ... is RJ 45 instead of RS 232 remove the adapter on the end of the serial cable and insert the exposed RJ 45 connector into the RJ 45 serial port on the workstation 2 Disable any serial communication programs running on the workstation 3 Open a terminal emulator such as HyperTerminal on a PC or TERM TIP or Kermit in a UNIX environment and configure as follows For most Windows systems Bits per second...

Страница 17: ...64 2 Provide the following network information for an IPv4 address a Ethernet IP address 192 168 74 102 b Ethernet subnet mask 255 255 255 0 c Gateway IP address 192 168 74 1 3 When prompted enter off to disable DHCP DHCP OFF off 4 Verify the IP address by entering the ipaddrshow command at the prompt 5 Record the IP address on the pull out tab on the port side of the switch 6 If the serial port i...

Страница 18: ...entral switch admin tstimezone Time Zone US Pacific switch admin tstimezone US Central switch admin tstimezone Time Zone US Central 3 Optional Use tstimezone interactive to select your time zone through an interactive menu Synchronizing local time using NTP To synchronize the local time using NTP Procedure 1 Log in to the switch using the admin account The default password is password 2 Enter the ...

Страница 19: ...er into a regular SFP transceiver you may damage the cable Do not attempt to insert a standard SFP cable into an mSFP transceiver you can damage the transceiver NOTE Only HPE B series or Brocade branded optical transceivers are supported Procedure 1 Install the SFP or QSFP SN6600B 32Gb FC Switch only transceivers in the appropriate FC ports on the switch to match the port type Remove any protector...

Страница 20: ... mechanism clicks 1 Pull tab 2 QSFP cable 3 QSFP transceiver Figure 12 Inserting a QSFP transceiver in an FC port SN6600B 32Gb FC Switch only 2 Connect the FC cables from the switch to your host and storage devices a Remove the plastic protector caps from the FC cable ends if there are any and position the cable connector so that it is oriented correctly b Position a cable so that the key the ridg...

Страница 21: ...more information on this command see the Fabric OS Command Reference Manual 2 Obtain the WWN from the Switch ID pull out tab located on the port side of your switch You can also use the switchshow or licenseidshow command to display the WWN 3 Contact your Hewlett Packard Enterprise representative to purchase the appropriate Port Upgrade license Hewlett Packard Enterprise requires the switch WWN ob...

Страница 22: ...r a list of available features for each mode and AG restrictions see the Access Gateway Administrator s Guide Disabling and enabling AG mode NOTE You can disable and enable AG mode using Web Tools For more information see the Web Tools Administrator s Guide Enabling AG mode To enable AG mode using Fabric OS commands Procedure 1 Before enabling AG mode save the current configuration file using the ...

Страница 23: ...ss the power switches Power is supplied to the switch as soon as the first power supply is connected and powered on To power the switch off power off the power supplies present by setting the AC power switch to O All devices are returned to their initial state the next time the switch is powered on LEDs The switch LEDs indicate system activity and status There are three LED states no light a stead...

Страница 24: ...t group 0 SFP FC ports 0 7 Figure 13 LEDs on the port side of the HPE StoreFabric SN3600B 32Gb FC Switch 1 System status LED 2 System power LED 3 FC port status LED port 0 4 FC port status LED port 4 5 FC port status LED port 52 6 FC port status LED port 53 7 FC port status LED port 54 8 FC port status LED port 55 9 FC port status LED port 60 10 FC port status LED port 61 11 FC port status LED por...

Страница 25: ...ernal power supply failure Verify the system is powered on power supply switches set to I the power cables are attached and the power source is live The unit may be faulty Contact your switch service provider Steady green System is on and power supplies are functioning properly No action is required System status LED No light System is off or there is no power Verify the system is on and has compl...

Страница 26: ... state Verify the power LED is on and check the SFP and cable Verify the device is not being initialized Verify the status of the connected device Steady amber Port is receiving light or signal carrier but not online No action is required Slow blinking amber 2 seconds Either the port has been disabled by diagnostic tests running or was disabled from executing the portdisable CLI command Verify the...

Страница 27: ...pply and fan assembly QSFP port status LED HPE StoreFabric SN6600B 32Gb FC Switch only No light Indicates one of the following There is no light or signal carrier on the media interface Device may be initializing Connected device is configured in an offline state Verify the power LED is on and check the QSFP and cable Verify the device is not being initialized Verify the status of the connected de...

Страница 28: ...red Slow blinking green 1 2 seconds The port is online but is segmented due to a loopback cable or incompatible device connection Verify that the correct device is attached to the switch Flickering green The port is online with frames flowing through the port No action is required 28 Login and Configuration ...

Страница 29: ... support sn3600b manuals SN6600B http www hpe com support sn6600b manuals Hewlett Packard Enterprise Websites For additional information see the following Hewlett Packard Enterprise websites http www hpe com http www hpe com info storage http www hpe com storage spock http www hpe com support downloads Resources and other information 29 ...

Страница 30: ...m 12 06 inches Width 42 88 cm 16 88 inches Weight with power supply and fan assemblies and no transceivers installed 4 2 kg 9 3lb Table 4 HPE StoreFabric SN6600B 32Gb FC Switch physical specifications Dimension Value Height 4 39 cm 1 73 inches Depth 35 56 cm 14 00 inches Width 44 00 cm 17 32 inches Weight with two power supplies and fan assemblies and no transceivers installed 7 71 kg 17 00lb 30 S...

Страница 31: ...9 47 cmh 35 cfm Ambient air temperature not exceeding 40 C 104 F while the switch is operating Rack when rack mounted 1U in a 48 3 cm 19 in cabinet All equipment in rack grounded through a reliable branch circuit connection Additional weight of switch not to exceed the rack s weight limits Rack secured to ensure stability in case of unexpected movement Power supply specifications The power supplie...

Страница 32: ...Condition Acceptable range during operation Acceptable range during nonoperation Ambient temperature 0º to 40ºC 32º to 104ºF 25º to 70ºC 13º to 158ºF Humidity 10 to 85 at 40ºC 104ºF 10 to 90 non condensing Altitude 0 to 3000 m 9 842 feet above sea level 0 to 12000 m 39 370 feet above sea level Shock 20 G 6 ms half sine wave 33 G 11 ms half sine wave 3G Axis Vibration 0 5 G sine 0 4 gms random 5 50...

Страница 33: ...ic initialization Complies with FC SW 3 Rev 6 6 FC IP Complies with FC IP 2 3 of FCA profile Local port latency HPE StoreFabric SN3600B 32Gb FC Switch 900 nanoseconds with no contention destination port is free including FEC using cut through frame switching HPE StoreFabric SN6600B 32Gb FC Switch 700 ns Data transmission ranges Table 9 HPE StoreFabric SN3600B 32Gb FC Switch and HPE StoreFabric SN6...

Страница 34: ...StoreFabric SN6600B 32Gb FC Switch only Memory specifications Table 10 Memory specifications for the HPE StoreFabric SN3600B 32Gb FC Switch and HPE StoreFabric SN6600B 32Gb FC Switch Memory type Size Boot flash 8 MB eUSB Module 2 GB Main memory DDR2 SDRAM HPE StoreFabric SN3600B 32Gb FC Switch 2 GB 64 bit HPE StoreFabric SN6600B 32Gb FC Switch 4 GB 64 bit FC port specifications The FC ports are co...

Страница 35: ...32Gb FC Switch Pin Signal Description 1 Not supported N A 2 Not supported N A 3 UART1_TXD Transmit data 4 GND Logic ground 5 GND Logic ground 6 UART1_RXD Receive data 7 Not supported N A 8 Not supported N A AG default port mapping Table 12 HPE StoreFabric SN3600B 32Gb FC Switch AG default port mapping Total ports F_Ports N_Ports Default port mapping 24 0 15 16 23 0 1 mapped to 16 2 3 mapped to 17 ...

Страница 36: ...ve component or assembly Grounding methods There are several methods for grounding Use one or more of the following methods when handling or installing electrostatic sensitive parts Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis Wrist straps are flexible straps with a minimum of 1 megohm 10 percent resistance in the ground cords To provide proper ground ...

Страница 37: ...rranties HPE Enterprise Servers www hpe com support EnterpriseServers Warranties HPE Storage Products www hpe com support Storage Warranties HPE Networking Products www hpe com support Networking Warranties Regulatory information Belarus Kazakhstan Russia marking Manufacturer and Local Representative Information Manufacturer information Hewlett Packard Enterprise Company 3000 Hanover Street Palo A...

Страница 38: ...clude YWW where Y indicates the year counting from within each new decade with 2000 as the starting point for example 238 2 for 2002 and 38 for the week of September 9 In addition 2010 is indicated by 0 2011 by 1 2012 by 2 2013 by 3 and so forth Turkey RoHS material content declaration Ukraine RoHS material content declaration 38 Turkey RoHS material content declaration ...

Отзывы: