Removing and replacing the M.2 enablement backplane
IMPORTANT:
The left and right sides of the chassis are oriented 180° from each other. Components
that are installed on one side of the chassis must be turned 180° when they are installed on the opposite
side.
Procedure
1.
Power down the server (
on page 28).
2.
Remove the server (
on page 28).
3.
Place the server on a flat, level work surface.
4.
Remove the access panel (
on page 29).
5.
on page 29).
6.
Disconnect the cable from the M.2 enablement backplane.
7.
Remove the M.2 enablement backplane.
To replace the component, reverse the removal procedure.
Removing and replacing the M.2 SSD drive
IMPORTANT:
The left and right sides of the chassis are oriented 180° from each other. Components
that are installed on one side of the chassis must be turned 180° when they are installed on the opposite
side.
Procedure
1.
Power down the server (
on page 28).
2.
Remove the server (
on page 28).
3.
Place the server on a flat, level work surface.
4.
Remove the access panel (
on page 29).
34
Removal and replacement procedures
Содержание ProLiant XL230k Gen10
Страница 5: ...Warranty information 72 Regulatory information 73 Documentation feedback 73 5...
Страница 22: ...22 Customer self repair...
Страница 23: ...Customer self repair 23...
Страница 24: ...24 Customer self repair...
Страница 25: ...Customer self repair 25...
Страница 49: ...6 Install the riser cover 7 Install the riser into the I O module Removal and replacement procedures 49...
Страница 61: ...Chassis server bay numbering Chassis I O module bay numbering Component identification 61...
Страница 65: ...Cabling Front panel LED board assembly cabling SATA drive cabling Cabling 65...