Power supply specifications
Depending on the installed options and the regional location where the server was purchased, the server can be
configured with one of the following power supplies:
•
HPE 500W Flex Slot Platinum Hot-plug Low Halogen Power Supply
•
HPE 800W Flex Slot Platinum Hot-plug Low Halogen Power Supply
•
HPE 800W Flex Slot Titanium Hot-plug Low Halogen Power Supply
•
HPE 800W Flex Slot Universal Hot-plug Low Halogen Power Supply
•
HPE 800W Flex Slot -48VDC Hot-plug Low Halogen Power Supply
•
HPE 1600W Flex Slot Platinum Hot-plug Low Halogen Power Supply
For detailed power supply specifications, see the QuickSpecs on the
Hewlett Packard Enterprise website.
HPE 500W Flex Slot Platinum Hot-plug Low Halogen Power Supply
Specification
Value
Input requirements
—
Rated input voltage
100 VAC to 240 VAC
240 VDC for China only
Rated input frequency
50 Hz to 60 Hz
Not applicable to 240 VDC
Rated input current
5.6 A at 100 VAC
2.7 A at 200 VAC
2.3 A at 240 VDC for China only
Maximum rated input power
557 W at 100 VAC
539 W at 200 VAC
537 W at 240 VDC for China only
BTUs per hour
1902 at 100 VAC
1840 at 200 VAC
1832 at 240 VDC for China only
Power supply output
—
Table Continued
Specifications
155
Содержание ProLiant DL385 Gen10
Страница 30: ...30 Customer self repair...
Страница 31: ...Customer self repair 31...
Страница 32: ...32 Customer self repair...
Страница 129: ...8LFF front panel 12LFF front panel Midplane box LFF only Component identification 129...
Страница 141: ...Rear 2SFF to system board Cable routing Front 8SFF SAS SATA drive options Box 1 to SAS Expander Cabling 141...
Страница 142: ...Boxes 2 and 3 to SAS Expander All boxes to SAS Expander 142 Cabling...
Страница 143: ...Cable routing Midplane 4LFF SAS SATA drive option Cabling 143...
Страница 145: ...Cable routing Rear 3LFF SAS SATA drive option for system board Cabling 145...
Страница 147: ...Cable routing Front 2SFF NVMe side by side drive options Cabling 147...
Страница 149: ...Cable routing Front 8SFF NVMe drive options Box 1 Box 2 Cabling 149...
Страница 150: ...Box 3 150 Cabling...
Страница 153: ...Cable routing Power switch module SID module An SFF model is shown The routing is the same for LFF Cabling 153...