Systems Insight Display LED
and color
Health LED System power
LED
Status
Over temp (amber)
Red
Amber
The server has detected a hardware critical
temperature level.
PCI riser (amber)
Red
Green
The PCI riser cage is not seated properly.
Fan (amber)
Amber
Green
One fan has failed or has been removed.
Fan (amber)
Red
Green
Two or more fans have failed or been
removed.
Power supply (amber)
Red
Amber
One or more of the following conditions
might exist:
• Only one power supply is installed and
that power supply is in standby.
• Power supply fault.
• System board fault.
Power supply (amber)
Amber
Green
One or more of the following conditions
might exist:
• Redundant power supply is installed and
only one power supply is functional.
• AC power cord is not plugged into
redundant power supply.
• Redundant power supply fault.
• Power supply mismatch at POST or
power supply mismatch through hot-
plug addition.
Power cap (off)
—
Amber
Standby.
Power cap (green)
—
Flashing green
Waiting for power.
Power cap (green)
—
Green
Power is available.
Power cap (flashing amber)
—
Amber
Power is not available.
IMPORTANT: If more than one DIMM slot LED is illuminated, further troubleshooting is required. Test each bank of
DIMMs by removing all other DIMMs. Isolate the failed DIMM by replacing each DIMM in a bank with a known
working DIMM.
116
Component identification
Содержание ProLiant DL385 Gen10
Страница 30: ...30 Customer self repair...
Страница 31: ...Customer self repair 31...
Страница 32: ...32 Customer self repair...
Страница 129: ...8LFF front panel 12LFF front panel Midplane box LFF only Component identification 129...
Страница 141: ...Rear 2SFF to system board Cable routing Front 8SFF SAS SATA drive options Box 1 to SAS Expander Cabling 141...
Страница 142: ...Boxes 2 and 3 to SAS Expander All boxes to SAS Expander 142 Cabling...
Страница 143: ...Cable routing Midplane 4LFF SAS SATA drive option Cabling 143...
Страница 145: ...Cable routing Rear 3LFF SAS SATA drive option for system board Cabling 145...
Страница 147: ...Cable routing Front 2SFF NVMe side by side drive options Cabling 147...
Страница 149: ...Cable routing Front 8SFF NVMe drive options Box 1 Box 2 Cabling 149...
Страница 150: ...Box 3 150 Cabling...
Страница 153: ...Cable routing Power switch module SID module An SFF model is shown The routing is the same for LFF Cabling 153...